Download Print this page

Pivot 52X-MN User Manual

Double gauge set for mini

Advertisement

Quick Links

USER' S MANUAL
Thank you for purchasing this PIVOT product.
Please read this manual carefully and keep it for future refer-
ence.
● If this produc t is given to
Product
another user, make sure to
include this User' s Manual.
Contents
Contents / WARNING / CAUTION ...... 1
Features ....................................... 1
Part Names and Displays .................. 2
Connecting The Wires and
Installing The Product ............... 2 ~4
Basic Operation .............................. 4
Troubleshooting .............................. 4
1. The display will not be proper if the ECU being used is not the standard one or if a sub-computer is being used, even in
compatible car models.
2. Cannot be used in combination with other company' s products that use Diagnostic Monitoring Connectors.
3. For details about using in combination with other PIVOT products that use Diagnostic Monitoring Connectors please see our
Web Site at ⇒ h t t p://p ivo t j p.c o m /o b d - e /.
4. The meter holder can become extremely hot when exposed to direct sunlight; be particularly careful of burns.
Improper use or disregard of these
WARNING
warnings may result in the injur y or
death of people.
●Do not work in areas where there is excessive exhaust.
Due to vehicle exhaust emission poisoning or fire may result in a
damage to humans.
●Do not crush the cable.
Please be careful that the cable does not get crushed by the seat rail or
car door steel plate, nor cut by any sharp steel plate as this may cause
a poor connection or an electric short leading to fire or other danger.
●Do not operate while driving.
Operating or checking the display during driving may cause an
accident; please use with the utmost consideration for safety.
●Please securely fasten the product to a stable place and
be sure to store bundle away all wires with tape, etc...
It is very dangerous to pull tangled wires by force or allow tangled wires
to interfere with driving.
Features
Just by connecting to the diagnostic monitoring connector, the MINI specialized CAN communication can be analyzed and
Boost and Water temperature data can be simultaneously displayed. (Not for use with incompatible models)
Simple Connector Installation Install by simply connecting to the diagnostic monitor connector and fuse box.
Specialized Meter Holder
LED Illumination
Please check the contents of the package
Voltage
Water Temp
Meter
Meter
Meter Holder
Gauge Cable
×2
●This product is for DC12V cars;
●Just after installation do not exert any strong force on the product.
●Do Not Use Chemical Cleansers.
●Do not install the product in any place subject to high temperature or any
●Make sure to replace all screws and parts to their original place.
●Do not install the product in a place where it will cause distraction.
●Do not, in any manner, process, take apart, or make changes to this product.
Lightweight meter holder with superior adhesion means less movement under vibration.
Uses same orange Illumination as that of standard meters.
Unit
OBD Cable
with fuse 3A
Tap Screw
Cushion
×3
×2
Tape
× 2
CAUTION
Improper use or disregard of these warnings may cause injury
to persons, damage the product and other things.
Installation cannot be carried out on cars with other voltage batteries.
When double-sided tape is used for an installation be warned that when hot the tape temporar-
ily losses adhesiveness.
If the unit gets dirty please wipe with a soft cloth to remove any dirt. Do not use chemical
cleansers such as thinner, benzene, or alcohol.
place where water may be splashed.
(52X-MN As of November, 2014 No.1)
Double Gauge Set for MINI
52X-MN
Fuse Power Cable
Cut
with fuse 3A
Connector
Double-sided
Double-sided
Tape
Tape
(round) × 4
(square)
Zip Ties
(Large) × 2
(Small) × 5
User' s
Manual
1

Advertisement

loading

Summary of Contents for Pivot 52X-MN

  • Page 1 2. Cannot be used in combination with other company’ s products that use Diagnostic Monitoring Connectors. 3. For details about using in combination with other PIVOT products that use Diagnostic Monitoring Connectors please see our Web Site at ⇒ h t t p://p ivo t j p.c o m /o b d - e /.
  • Page 2: Part Names

    Displays and Uses Part Names 【Meter】 【Unit】 Boost Water Temperature (Absolute pressure display) Bezel (View from Meter Connection) Display Display 0 ∼154kPa 20˚C〜120˚C Dial Prevention of overheating Check Boost etc. Check Heating etc. Needle (View from Car Connection) Shows the WATER current values.
  • Page 3 Meter Holder (Backside) When installing the 52X-MN please m a k e a d j u s t m e n t s t o l i n e u p t h e ①...
  • Page 4: Basic Operation

    ※We plan in the near future to take all possible legal measures to protect against unfair competition from look-alike products using similar designs, regulating characteristics, circuitry and circuitry layout. ※We strictly prohibit the unlicensed use of the PIVOT trademark and the unauthorized use of PIVOT User’ s Manual. PIVOT CORPORATION...