INSTALLER OPTIONS

These set up features should only be accessed by a qualified installer during initial EvenAir thermostat
installation set up. The homeowner would not normally access these product set up features.
Option
Description
01
Equipment Type
02
Heat Pump Type
(HP Only )
03
OBP Outdoor Balance Point
04
Compressor Stages
05
Heating Stages
06
Fan Operation.
(GE Only)
07
Compressor Minimum Off Time (minutes).
08
Gas Heating Minimum Off Time (minutes).
09
Minimum Run Time (minutes).
10
On-Off Temperature Differential
o
0 Cooling On 1 above setpoint, Off at setpoint. Heating On1 below setpoint, Off at setpoint.
o
1 Cooling On 1 above setpoint, Off .5 below setpoint. Heating On1 below setpoint, Off .5 above setpoint.
o
2 Cooling On 1 above setpoint, Off 1 below setpoint. Heating On1 below setpoint, Off 1 above setpoint.
11
Smart Recovery.
Upstaging Time
12
13
Vacant Heating Setpoint.
14
Vacant Cooling Setpoint.
Calibrate Living Area Sensor
15
16
Calibrate Sleeping Area Sensor.
17
Night Level LCD Backlight
Fresh Air Control per ASHRAE 62.2
20
21
Minutes of Fresh Air per Hour
22
Inhibit Fresh Air Using Temperature Limits
Fresh Air High Temperature Limit
23
Fresh Air Low Temperature Limit
24
25
Enable Indoor Fan VENT Mode
30
Whole House Fan Control
Economizer using Dampers and Equipment Fan
31
32
Economizer or WHFan controlled by temperature
33
Economizer or WHFan OD temperature differential
Economizer or WHFan controlled by Timer
34
Humidifier Control
40
41
Automatic Adjustment of Humidity Setpoint
42
De-Humidification Control
50
Airflow Control
Airflow Update Time
51
52
Enable User Airflow Control
Maximum Airflow in Heating to the Sleeping Area.
53
54
Maximum Airflow in Cooling to the Sleeping Area.
55
Maximum Airflow in Heating to the Living Area.
56
Maximum Airflow in Cooling to the Living Area.
57
Maximum Temperature Difference Between
Sleeping and Living area.
Home Number
58
Thermostat Location
59
Factory Restore
60
INSTALLER SECTION
Display
HPt
(Dual fuel HP Only )
OBP
CPr
HtG
FAn
COt
HOt
r n t
O O d
o
o
S r
USt
V A C
V A C
C A L
C A L
BL
FAC
FAt
FAL
FtH
FtL
FCt
HFn
EFn
EtL
EOd
Etr
HFc
HFA
dHF
AFC
AFt
UAC
HAF+Heat
CAF+Cool
HAF+Heat
CAF+Cool
diF
Home
tLo
Fr
page 9 of 16
Range
GE or HP
Co(conv) or dF (dual fuel)
35 to 55F
0, 1 or 2
0, 1 or 2
GA(Down) or EL(Up)
0 to 9
0 to 9
0 to 9
0, 1 or 2
o
o
o
0n(Up) or Off(Down)
5 to 30 minutes
+ Heat
44 to 75F
+ Cool
74 to 95F
+/- 5F
+/- 5F
+ Night
On(Up) or Off(Down)
On(Up) or Off(Down)
0 to 60 minutes
On(Up) or Off(Down)
65 to 100F
0 to 65F
On(Up) or Off(Down)
On(Up) or Off(Down)
On(Up) or Off(Down)
On(Up) or Off(Down)
0 to 10F
On(Up) or Off(Down)
On(Up) or Off(Down)
On(Up) or Off(Down)
On(Up) or Off(Down)
On(Up) or Off(Down)
1 to 20 minutes
On(Up) or Off(Down)
100 to 160%
100 to 160%
100 to 160%
100 to 160%
0 to 10F
1 to 8
dS or uS
No or Yes
Default
As Installed
GE
Co
40F
1
1
GA
2
0
2
1
o
o
Off
10
65F
80F
na
na
On
Off
30
Off
95F
35F
Off
Off
Off
Off
0F
Off
Off
Off
Off
On
2
Off
150%
140%
150%
140%
2F
1
dS
No
P/N 780101708 2/18 Rev A