58 Home Number for
Wireless Sensors
Factory Default: 1. Range: 1 to 8.
The Home number is used in wireless
communications with the wireless sensors and
used to distinguish homes when they are within
300 feet of one another. If the homes are within
300 feet and both are using wireless
temperature sensors, one of the homes needs to
be changed to a different Home number. The
wireless sensor home number also has to be
changed and is described in the Wiring Hub
Installation manual.
Use the
UP/DOWN
Option
keys to select a new
Home number.
Touch NEXT
or
ENTER.

59 Thermostat Location

Factory Default: dS. Range: dS or uS
The thermostat is normally located downstairs in
the living area. If the thermostat is located
upstairs in the sleeping area, this option can be
used to change the location to upstairs.
Use the Up key to
Option
select uS, upstairs in
the sleeping area or
use the Down key to
select dS, downstairs in
the living area.
Touch NEXT
or
ENTER.
60 Factory Restore
WARNING! Factory Restore resets ALL settings.
To exit this option, touch
NEXT
or
hidden Back key.
To restore factory settings, touch the
display YES then touch ENTER.
INSTALLER SECTION
!
Install batteries only after
s u c c e s s f u l l y
installation by initiating a
heating call, cooling call and
fan call.

INSTALL BATTERIES

The batteries power
the clock when
24VAC power is lost.
Home
Slide the battery
cover downward
and install the two
AA batteries as
NEXT
ENTER
shown.

SET TIME and DAY

Touch here to change
the time and day of
the week. See page 4.
NEXT
ENTER
ENTER, or the
UP
key to
!

ERROR MESSAGES

Option
No Communication Message
nC is displayed briefly when the wiring hub and
thermostat are powered up and the thermostat is
establishing communication with the wiring hub.
NEXT
ENTER
Or, nC will be displayed if the thermostat has lost
communication with the wiring hub.
Option
If the message continues to be displayed after
about 10 seconds, turn off the power and check
the wiring between the thermostat and wiring hub
NEXT
ENTER
and ensure the wires are secured in the correct
terminals at the thermostat and wiring hub.
t e s t i n g
t h e
Sleeping
Airflow %
Cool
Set To
Schedule
Living
Living
Day
COOL
Tu
SYSTEM
AM
AUTO
MENU
MODE
FAN
Sleeping
Heat
Airflow %
Set To
Hold
Living
HEAT
Living
We
SYSTEM
AM
AUTO
MENU
MODE
FAN
page 13 of 16
No Power
If the the LCD is blank there is no power from the
wiring hub. Check the red LED power indicator
on the Wiring Hub. If it is On check the wiring
from the thermostat to the wiring hub.
If the Red LED on the wiring hub is off, check the
24VAC at the equipment R and C and the wiring
between the wiring hub and the equipment.
Sensor Error Message
nS is displayed when there is an error with the
temperature sensor(s). For wired sensors, turn off
the power and check the wiring between the
sensor and wiring hub and that the wires are
secured in the correct terminals on the sensor
and wiring hub.
For wireless sensors,
Sleeping
ensure that batteries
Airflow %
are installed in the
Living
Day
Tu
wireless sensor and
AM
that the wireless
MENU
MODE
sensor is set to the
correct number.
When the nS message is displayed, the
thermostat will continue to control the system and
automatically fully opens both dampers and
disables airflow control until the sensor error is
corrected.
Wireless Sensor Error Message
The thermostat displays the Snr 01 or Snr
02 message when communication with a
wireless sensor has been lost for over 15
minutes. Check the batteries in the sensor
and ensure the sensors are set to the
correct sensor number. To check sensor
communication, place your finger over the
thermistor on the right side of the sensor to
increase the temperature detected. The
wireless sensor sends a signal to the
thermostat when a change in temperature
occurs or every 15 minutes. The thermostat
should clear the message. If the error
persists, turn off power to the wiring hub.
When power is restored, the wiring hub
automatically detects which sensors are
being used and clears the error message.
Sleeping
Airflow %
Living
Day
Tu
MENU
MODE
Indicates an error
with sensor #1.
Indicates an error
with sensor #2.
P/N 780101708 2/18 Rev A
Cool
Set To
Schedule
Living
COOL
SYSTEM
AUTO
FAN
Cool
Set To
Schedule
Living
COOL
SYSTEM
AUTO
FAN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evenair t32wf

Table of Contents