ACCESSING INSTALLER OPTIONS
To access the Installer Options,
TOUCH
HOLD
the hidden Enter key for 7 seconds until
the first Option appears on the screen.
Sleeping
Airflow %
Schedule
Living
Day
Tu
AM
MENU
MODE
TOUCH
and
The hidden BACK
for 7 seconds to access the
key can be used to
Installer Options.
return to previous
options.
Press the touchscreen with your fingertip
!
only, using a firm touch. Do not use a sharp
object such as a pen or pencil.
!
The NEXT key is used to display the next
option.
The ENTER key is used to save options and
!
return to normal thermostat operation.
The hidden BACK key is used to return to
!
previous options and is located to the left of
the NEXT key.
01 Equipment Type
Factory Default: GE. Range: GE or HP
This option is used to
Option
select gas/electric or
heat pump
equipment.
Use the UP/DOWN
keys to select
gas/electric (GE) or heat pump (HP).
Touch NEXT or ENTER.
02 Heat Pump Type
(Only displayed if Heat Pump equipment)
Factory Default: Co. Range: Co or dF
Select a
Option
conventional (Co)
HP or a dual fuel
(dF) HP with fossil
fuel auxiliary heat.
Use the UP/DOWN
keys to select Co or dF type HP .
Touch NEXT or ENTER.
INSTALLER SECTION
03 Outdoor Balance Point
(Only displayed if Heat Pump and Dual
and
Fuel selected.)
Requires TS3 Outdoor Temperature Sensor
to be installed. (see wiring hub, H32,
installer manual)
Factory Default: 40F. Range: 35F to 55F
Cool
Set To
Use the UP/DOWN
keys to select the
Living
COOL
outdoor temperature
for switching to fossil
SYSTEM
fuel heating in a dual
AUTO
fuel heat pump.
FAN
Touch NEXT or ENTER.
HOLD
this key

04 Compressor Stages

Factory Default: 1 Stage. Range: 0,1 or 2
Use the UP/DOWN
keys to set 0, 1 or 2
stages.
Touch NEXT or ENTER.
05 Heating Stages
Factory Default: 1 Stage. Range: 0,1 or 2
If GE equipment is selected, this option determines
the number of heating stages - 0, 1 or 2 stages. If
HP equipment is selected, this option determines
the number of auxiliary heating stages - 1 or 1.
Use the UP/DOWN
keys to set 0, 1 or 2
stage for a GE system
or 0 or 1 stage for HP
auxiliary heating
stages.
Touch NEXT or ENTER.
NEXT
ENTER

06 Fan Operation

(Only displayed if Gas/Electric equipment.)
Factory Default: Gas. Range: GA or EL
Use the UP key to
select "EL" for electric
operation where the
thermostat activates
the indoor fan (G
terminal) during
heating calls or DOWN key to select GA for gas
operation where the equipment plenum sensor
activates the indoor fan in heating calls.
Touch NEXT or ENTER.
NEXT
ENTER
07 Compressor Minimum Off Time
Factory Default: 2 Minutes. Range: 0 to 9 Minutes
Use the UP/DOWN
keys to change the
minimum off time
(minutes) before
restarting the
compressor.
Touch NEXT or ENTER.
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
page 10 of 16
08 Gas Heating Minimum Off Time
Factory Default: 0 Minutes. Range: 0 to 9 Minutes
Use the UP/DOWN
keys to change the
minimum off time
(minutes) before
restarting a gas
furnace or electric
strip heater.
Touch NEXT or ENTER.

09 Minimum Run Time

Factory Default: 2 Minutes. Range: 0 to 9 Minutes
Use the UP/DOWN
keys to change the
minimum run time
(minutes) before
turning a system off.
Touch NEXT or ENTER.
10 On-Off Temperature Differential
Factory Default: #1. Range: 0, 1 or 2.
Use the UP/DOWN
keys to select 0, 1, 2.
Touch NEXT or ENTER.
o
Mode0
1.0 On/Off Span.
o
Mode1
1.5 On/Off Span.
o
Mode2
2.0 On/Off Span.

11 Smart Recovery

Factory Default: Off. Range: On or Off.
Smart recovery initiates a heating or cooling call
so that the space is at temperature when the
setback period ends.
Use the UP key to
select ON to turn on
smart recovery or the
DOWN key to select
OF to turn smart
recovery off.
Touch NEXT or ENTER.
12 Upstaging Time
Factory Default: 10 minutes. Range: 5 to 30 minutes
Use the
UP/DOWN
keys to set the time at
which second stage
heating or cooling is
activated.
Touch
NEXT
or
ENTER.
13 Vacant Heating Setpoint
Factory Default: 65F. Range: 44F to 75F
Use the UP/DOWN
keys to select the
heating temperature
when the space is
vacant.
Touch NEXT or ENTER.
P/N 780101708 2/18 Rev A
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
Heat
Vacant
NEXT
ENTER