Economizer Control; High Temperature Limit; Low Temperature Limit - Field Controls EvenAir T32 Installation And User Manual

Thermostat with airflow control
Table of Contents

Advertisement

14 Vacant Cooling Setpoint
Factory Default: 80F. Range: 74F to 95F
Use the
UP/DOWN
keys to select the
cooling temperature
when the space is
vacant.
Touch
NEXT
or
ENTER.
15 Calibrate Living Area
Temperature Sensor
Factory Default: None. Range - +/-5
Use the UP/DOWN
keys to change the
Living area
temperature to the
temperature that the
user feels is correct.
Touch NEXT or ENTER.
16 Calibrate Sleeping Area
Temperature Sensor
Factory Default: None.
Range - +/-5
Use the UP/DOWN
keys to change the
Sleeping area
temperature to the
temperature that the
user feels is correct.
Touch NEXT or ENTER
17 Night Level LCD Backlight
Factory Default: On. Range: On or Off.
The LCD has a low
level backlight that
can be used as a
Night
night light.
Use the UP key to turn
the low level backlight ON or touch the
key to turn OFF.
Touch
NEXT
or
ENTER.
For Fresh Air Control wiring information, see
!
the H32 Wiring Hub Installer Manual.
20 Fresh Air Control
per ASHRAE 62.2
Factory Default: OFF. Range: On or Off.
Select ON to enable Fresh Air Control. Fresh air
damper opens and an optional ERV or HRV is
activated.
Option
Use the
UP
key to
select ON or touch the
DOWN
key to select
OFF.
Touch
NEXT
or
ENTER.
INSTALLER SECTION
21 Minutes of Fresh Air per Hour
(Only displayed if Fresh Air Control is ON)
Factory Default: 30 minutes. Range: 0 to 60.
Option
Cool
Select the number of minutes the fresh air
Vacant
damper should open each hour based on
ASHRAE 62.2 calculations and damper size.
NEXT
ENTER
Use the
UP
increase the fresh air
minutes or the DOWN
key to decrease the
minutes.
o
Touch
NEXT
Option
22 Inhibit Fresh Air Using
Temperature Limits
Living
(Only displayed if Fresh Air Control is ON)
Factory Default: OFF. Range: On or Off.
NEXT
ENTER
Select ON to inhibit fresh air control using outdoor
temperature limits set in options 23 and 24.
Use the
UP
select ON or touch the
DOWN
key to select
OFF.
o
Touch
NEXT
Option

23 High Temperature Limit

Sleeping
(Only displayed if Temperature Limits is ON)
Factory Default: 95F. Range: 65F to 100F.
NEXT
ENTER
Select the maximum outdoor temperature for
fresh air damper operation.
Use the UP key to
increase the
temperature limit or
the DOWN key to
decrease the
Option
temperature limit.
Touch NEXT or ENTER.

24 Low Temperature Limit

NEXT
ENTER
(Only displayed if Temperature Limits is ON)
DOWN
Factory Default: 35F. Range: 0F to 65F.
Select the minimum outdoor temperature for
fresh air damper operation.
Use the UP key to
increase the
temperature limit or
the DOWN key to
decrease the
temperature limit.
Touch
NEXT
25 Enable Fan VENT Mode
(Not displayed if Fresh Air, Whole
House Fan or Economizer Control is ON)
Factory Default: OFF. Range: On or Off.
Select ON to enable Fan VENT mode. In VENT
mode the indoor fan turns on to circulate air if a
heating or cooling call has not occurred in 120
minutes.
NEXT
ENTER
Use the
UP
select ON or touch the
DOWN
key to select
OFF.
Touch
NEXT
key to
Option
NEXT
ENTER
or
ENTER.
key to
Option
or
ENTER.
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
or
ENTER.
key to
Option
or
ENTER.
NEXT
ENTER
page 11 of 16
For Whole House Fan or Economizer wiring
!
information, see the H32 Wiring Hub
Installer Manual.
30 Whole House Fan Control
Factory Default: OFF. Range: On or Off.
Select ON if a whole house fan is controlled by
the thermostat.
Use the
UP
key to
select ON or touch the
DOWN key to select
OFF.
Touch NEXT or ENTER.

31 Economizer Control

(Only displayed if Whole House Fan Control is OFF)
Factory Default: OFF. Range: On or Off.
Select if dampers and the equipment fan is used
to bring in cool outdoor air for cooling. See the
Wiring Hub Installation for different economizer
configurations.
Use the
UP
key to
select ON or touch the
DOWN
key to select
OFF.
Touch
NEXT
or
ENTER.
32 Economizer/Whole House Fan
Control by Temperature
(Only displayed if Whole House Fan or
Economizer Control is ON)
Factory Default: OFF. Range: On or Off.
Select ON to control the Whole House Fan or
Economizer using the outdoor, room and cooling
setpoint temperatures. See Option 34 to control
using a timer
Use the
UP
key to
Option
select ON or touch the
DOWN
key to select
OFF.
Touch
NEXT
or
ENTER.
33 Economizer or Whole House Fan
Outdoor Temperature Differential
(Only displayed if Economizer/Whole House
Fan Control by Temperature set to ON)
Factory Default: 0. Range: 0-10 degrees.
Select the number of degrees the outdoor
temperature must be below the room
temperature to activate the Economizer or Whole
House Fan.
Use the
UP and
Option
D
OWN key to change
the temperature
differential.
Touch
NEXT
or
ENTER.
P/N 780101708 2/18 Rev A