Thermostat Overview - Field Controls EvenAir T32 Installation And User Manual

Thermostat with airflow control
Table of Contents

Advertisement

Thank you for purchasing the EvenAir System from Field Controls. The EvenAir products are compatible
with any HVAC system having accessible 24VAC terminals.
FEATURES
SYSTEM MODES
Off, Heat, Cool, Auto. EHeat or emergency heat is available
when heat pumps are used. ECool is available to control a
whole house fan or economizer when installed.
FAN MODES
Auto, On (Continuous) or Vent
THERMOSTAT MODES
Hold, Schedule or Vacant
HUMIDITY
Monitors and displays indoor relative humidity from10 to 80%.
PROGRAMS PER DAY
Morning, Daytime, Evening and Night
PROGRAM FORMAT
Weekdays and weekend – 5/2
TEMPERATURE OVERRIDE
Temperature is held for 3 hours when adjusted in Schedule
mode.
AIRFLOW OVERRIDE
The airflow to the living area or sleeping area can be adjusted.
After 3 hours, the thermostat returns to automatic airflow
control.
AIRFLOW CONTROL
Airflow control can be turned off and the thermostat will operate
as a typical thermostat.
AIRFLOW LIMITS
Maximum airflow limits can be set for heating and cooling
modes during installation.

THERMOSTAT OVERVIEW

Press the touchscreen with your fingertip only, using a firm touch. Do not use a sharp object such as a pen or pencil.
!
The touchscreen is a resistive touch and responds differently than touchscreens found in smart phones/devices.
Displays the Thermostat Mode
HOLD, SCHEDULE or VACANT
Displays the sleeping area airflow
Displays the living area airflow
Displays the time, day and
schedule. MORNING, DAYTIME,
EVENING or NIGHT
MENU Key
Displays User options.
MODE Key
Selects Thermostat Mode
HOLD, SCHEDULE or VACANT
NIGHTTIME OPERATION
At night, the EvenAir thermostat uses the temperature sensor in
the sleeping area to control heating and cooling calls and
directs more airflow to the sleeping area.
COMPATIBLE EQUIPMENT
Gas/electric equipment with 2-stage heating and 2-stage
cooling or conventional or dual fuel heat pumps with 2
compressor stages and 1 auxiliary heating stage.
TEMPERATURE SENSOR
Wired or wireless temperature sensors can be used in the
sleeping area. For wired sensors, use one TS51 sensor or two
TS52 temperature sensors. For wireless sensors, use one or two
TSER wireless sensors. Wireless sensors require the ER1
electronic receiver module to be installed in the wiring hub.
MODULATING DAMPERS
Round or rectangular dampers using the AMJ actuator and up
to 1 inch static pressure.
FRESH AIR CONTROL PER ASHRAE 62.2
Controls a fresh air damper. Set minutes per hour of fresh air
operation. Set temperature limits for fresh air operation.
WHOLE HOUSE FAN/ECONOMIZER CONTROL
Controls different whole house fan/economizer configurations
for eCooling using a timer or true temperature control.
HUMIDIFIER CONTROL
Controls a humidifier during heating using relay contacts.
POWER
Thermostat is powered by the wiring hub that operates on
24VAC from the HVAC equipment using the R and C wires.
R
Sleeping
Airflow %
Schedule
Living
Day
Tu
AM
MENU
MODE
page 2 of 16
Displays the heating or
cooling setpoint temperature
or the humidity (RH%) setpiont.
UP/DOWN Keys
Cool
Displays the living area,
Set To
sleeping area or outdoor
temperatures or indoor RH%.
COOL
Living
SYSTEM MODE Key
SYSTEM
OFF, HEAT, COOL, AUTO,
AUTO
EHEAT or ECOOL
FAN
FAN MODE Key
AUTO, ON or VENT
ENTER Key
Used to save options and
return to thermostat operation
NEXT Key
Used to advance through options
P/N 780101708 2/18 Rev A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evenair t32wf

Table of Contents