INSTALLATION

Homes with plaster walls with steel lathe may
experience wireless communication interference
when using wireless sensors. Wired sensors are
recommended.
!
CAUTIONS
Before installing the EvenAir comfort system, turn off
all power to your HVAC system.
Read and follow all instructions carefully.
Read entire manual before installing EvenAir products.
Follow all local electrical codes during installation. All
wiring must conform to local and national electrical
codes.
Use cautions when mounting components to surfaces
that may have concealed wiring beneath the surface.
When servicing EvenAir system or accessing products,
turn off all power to these items.
ATTENTION INSTALLER
1)
Install and wire components to the wiring hub. (See
H32 Wiring Hub manual for wiring detail)
2)
If wireless sensors are used, install the ER1 electronic
receiver module in the wiring hub and set the sensor
number and home number as necessary.
(see H32 Wiring Hub manual).
3)
Place the thermostat on the subbase. Do not install
batteries.
REMOVE SUBBASE
Place a slotted screwdriver in the
slots as shown and rotate to
remove subbase from the
thermostat housing.

INSTALLER SECTION

4)
5)
6)
7)
8)
ATTACH SUBBASE TO WALL
Attach the subbase to an interior wall and about 5-feet above
the floor as shown using the screws and wall anchors supplied.
The wires to the wiring
hub pass through the
opening.
page 7 of 16
Turn power to the HVAC equipment On.
Check for Start Up Messages/Errors.
Set equipment options 1-6 if different than factory
default settings. (see Installer Options section).
Test the installation by initiating a heating call, cooling
call and fan call.
Install batteries and set the time and day (see Installing
Batteries and Set Time and Day section)
Airflow Control Off Option 50 turns off Airflow Control.
The thermostat controls the system, dampers fully open,
nighttime airflow control is disabled and airflow is no
longer displayed on the thermostat.
User Airflow Control can be enabled using Option 52
User turns off automatic airflow control in the User
Options.
Nighttime Airflow Control is defaulted to ON. If
bedrooms are located downstairs, consider turning this
option Off using the User Options if bedrooms are not
on the same trunk.
Fresh Air Control is defaulted to Off and controlled by
Options 20 thru 25.
Whole House Fan or Economizer Control is defaulted
to Off and controlled by Options 30 thru 34.
Humidifier and De-Humidification Control is defaulted
to Off and controlled by Options 40 thru 42.
Airflow Control is defaulted to On and controlled by
Options 50 thru 57.
5 V
G N D
S A
S B
T3 2
P/N 780101708 2/18 Rev A