Control Module Handling Requirements; Removing A Control Module - Dell Equallogic PS6000 Hardware Maintenance

Storage arrays
Hide thumbs Also See for Equallogic PS6000:
Table of Contents

Advertisement

PS6000 Hardware Maintenance
Figure 3-3: Recommended Network Configuration

Control Module Handling Requirements

Follow these control module handling requirements:
Protect control modules from electrostatic discharge. Always wear an
electrostatic wrist strap when handling a control module, as described in
Using an Electrostatic Wrist Strap on page 1-5. When not installed, store a
control module in an antistatic bag or place it on a surface protected from
electrostatic discharge.
Do not remove a control module from an array while the control modules
are synchronizing. When synchronization completes, a console message will
appear. Also, the ACT LED on the secondary control module will be orange.
Do not leave a control module slot empty. In an array with one control
module, always attach a blank face plate to the empty control module slot.
Store control modules properly. Store a control module in its original
packaging or in an antistatic bag or place the control module on a surface
protected from electrostatic discharge.

Removing a Control Module

If a control module fails, remove it and replace it with a functioning control
module. Do not remove a failed control module until you are ready to replace it.
3–8