Maintaining Power Supply Modules; Interpreting The Leds; Identifying Failures - Dell Equallogic PS6000 Hardware Maintenance

Storage arrays
Hide thumbs Also See for Equallogic PS6000:
Table of Contents

Advertisement

4 Maintaining Power Supply Modules

A PS6000 array includes two hot-swappable, combination power supply and
cooling modules.

Interpreting the LEDs

Use the power supply and cooling module LEDs, shown in Figure 4-1 and
described in Table 4-1, to determine the module status and identify problems. The
power supply and cooling module LEDs show the power, fan, and array status.
Figure 4-1: Power Supply and Cooling Module LEDs
Table 4-1: Power Supply and Cooling Module LEDs
LED
Color
Off
Orange
Off
Orange
Off
Orange
Off
Green

Identifying Failures

You can identify a power supply and cooling module failure by any or all of the
following:
LEDs. See Interpreting the LEDs on page 4-1.
Messages. A message on the console, in the event log, or in the Group
Manager GUI Alarms panel describes a power supply and cooling module
failure.
Description
Normal operation.
DC power failure.
Normal operation.
Fan failure.
Normal operation.
AC power failure.
No power.
Normal operation.
4–1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents