PARAMETERS PAGE
Every parameters modification/adjustment should be performed by very skilled technician. It's advisable to keep a backup copy of the manufacturer value.
The parameters page consists of 4 submenu:
PARAMETERS, VACUUM PARAMETER, TEMEPERATURE PARAMETERS, GENERAL
HOURS N°: N° working hours
CYCLE N°: N° lamination cycles done
ALLARM RAW: Alarms view
Linearization parameters regarding the upper/lower vacuum gauge by the follow
function: VacuumUP/DW = m * (Sensor Value) + q
Where "m" and "q" are set parameters
Time in seconds after which laminator stops the
cover opening. Changing this value you can modify the height of the cover when it's
open.
Overrun Time in ms after closing cover point from limit switch. This extra time is
useful when the cover close without hermetic sealing and it's necessary to manually
force down the cover.
Parameters regarding the vacuum pipeline
This page contains the main temperature parameters regarding the automatic cycle,
the maximum temperature limit of tolerance to pass to next recipe step and the
intervention threshold of cooling circuit
By pushing the button "Use cooling system" is enabled or not the hydraulic cooling
system.
This page includes the general parameters of setting panel (Language, brightness of
the panel, date and time)