Electrical Connection - P. Energy L150A User And Maintenance Handbook

For photovoltaic panels with maximum dimension 1500x1000mm
Table of Contents

Advertisement

......................................................
3.1.
ELECTRICAL CONNECTIONS
All electrical connections must be provided by trained personnel.
Electrical specification:
The right values are showed on the CE laminator plate
Rated Power:
The value is showed on the CE laminator plate
Feeder cable:
The electrical connection with machine have to be done with a suitable cable (minimum cross section 4x6mm
length of 20 mt)
Connecting place:
- Connect the machine main switch to the power supply network through the cable gland behind the electric cabinet (see
the electric scheme).
In order to connect the machine it's necessary to remove the side casing and the column cover.
3.2.
PNEUMATIC CONNECTIONS
All pneumatic connections must be provided by trained personnel.
Min and Max working Pressure:
Air consuming:
60l/min
Pipe type:
Pneumatic connection must be done based on norm with a suitable pipe section
Connecting place:
the connection is made through the rear side input by a prepared hole on the column cover, (see position n. 21 of laminator
components view)
3.3.
HYDRAULIC CONNECTIONS
The Hydraulic connections must be provided by trained personnel.
Water consuming:
10 l/min (
Note: the water temperature influence the cooling cycle, check that the temperature input is suitable to the working cycle
Pipe type:
Hydraulic connection must be done based on norm with a suitable pipe section.
Connecting place:
the connection is made through the rear side input by prepared connection, (see position n.r 22 and 23 of the view of
laminator components view)
P.Energy
P.Energy
P.Energy
P.Energy
The working pressure is reported on the pneumatic scheme (Pmax=8bar; Pworking 6bar)
)
only if cooling is used
USER AND MAINTENANCE HANDBOOK L150A