For photovoltaic panels with maximum dimension 1500x1000mm
Table of Contents

Advertisement

......................................................
3.7.2-Touch screen Panel:
Touch screen allows to setup, monitor and edit the values of controller parameters, to monitor and manage alarms, manage recipes and
command directly the output.
- The display is used as input device for interacting with the display's field, removing the keyboard and the mouse.
-The numeric input data are edited according to following procedure:
1.Touch the input data field (after a keyboard touch will appear)
2.Edit the value by the keyboard touch
3.Confirm the value with the Enter button
4.The keyboard will disappears and the input value is stored in the PLC memory
HOMEPAGE TOUCHSCREEN
It's automatic loaded at start up
In the bottom of screen there are the "START", "P.Energy details" and "About Machinery" pushbuttons that allow access to general information concerning
manufacturer and machine type.All pages have in common the same top menu bar that allow access to the laminator control pages
CYCLE PUSHBUTTON: This page contains all working parameters, as actual recipe step, plate temperature, upper and lower vacuum chamber value. In
this page the operator starts the working cycle in automatic mode by the start cycle pushbutton. The cycle page contains a PLATE TEMPERATURE
submenu where it's possible to monitor the actual plate temperature detected through the temperature probes in order to verify the temperature
uniformity and the possible breaking of resistance.
PARAMETER PUSHBUTTON: This page contains the machine parameters essential in working mode. Every parameters modification/adjustment should
be performed by very skilled technician.
MANUAL MODE PUSHBUTTON: In this page it's possible to command in manual mode all the laminator functionality and verify the working status. The
manual commands are free without restrictions and not associated with the working mode. It's possible to test the follow laminator functionality:
1 Testing of vacuum circuit by the VACUUM COMAND submenu
2 Testing of heat resistance by setting temperature on HEAT. COMAND submenu
3 Opening/closing the cover in manual mode, enable/disable the cooling system, drain of water cooling circuit by the GENERAL COMAND submenu.
ALLARMS: This page contains details regarding the possible alarms and the reset command
It shows the machine operating status: prestart, manual o automatic mode
Stato:
???
Recipe: It contains all parameter concerning the working recipe used when the automatic cycle start
P.Energy
P.Energy
P.Energy
P.Energy