Wireless Dmx Interface Pcb Assembly Replacement - Philips Vari-Lite VL440 Service Manual

Table of Contents

Advertisement

M
AINTENANCE

Wireless DMX Interface PCB Assembly Replacement

WARNING: Ensure that power is completely removed (disconnected) from luminaire before
attempting any work.
To remove the wireless DMX interface PCB assembly:
Step 1. Ensure power is completely removed from luminaire and luminaire has cooled completely.
Step 2. Remove Ballast / LVS assembly as described in
page
WARNING: Do not set head on or damage front lens during next step!
Step 3. Carefully, flip luminaire to access bottom of enclosure. Do not set on lens.
Step 4. Remove six 1/4-20 x 1/2" PFZ screws and remove Bottom Plate from enclosure assembly.
Enclosure Assembly
1/4-20 x 1/2" PFZ Screw (x6)
NOTE:
Components removed and
exploded for clarity.
Step 5. At wireless DMX interface PCB assembly, disconnect all wiring.
02.96 87.001 0 0
P
: W
ROCEDURES
IRELESS
60.
Bottom Plate
Figure 2-50: Enclosure Assembly Bottom Plate Removal
DMX I
PCB A
NTERFACE
"Ballast / LVS Assembly Replacement" on
R
SSEMBLY
EPLACEMENT
2
67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vari-lite vl880Vari-lite vl770

Table of Contents