Zoom Module Assembly Removal

WARNING: Ensure that power is completely removed (disconnected) from luminaire before
attempting any work.
To remove zoom module assembly:
Step 1. Remove power from luminaire and allow unit to completely cool.
Step 2. Remove front and rear cover assemblies (see
and
Step 3. Remove Gobo Module Assembly as described in
page
Step 4. At Driver Board, disconnect Zoom Module Harness. Cut any cable ties and pull harness
free. DO NOT cut any wires.
Step 5. As indicated in
assembly open.
CAUTION:
02.96 87.001 0 0
M
AINTENANCE
"Rear Cover Assembly Removal" on page
23.
Figure
2-8, loosen captive screw and carefully tilt MCU/Driver Board
MCU / Driver Assembly
Captive Screw
Remove power and
allow fixture to cool.
Figure 2-8: MCU Assembly Captive Screw
P
: Z
M
ROCEDURES
OOM
"Front Cover Assembly Removal" on page 19
20).
"Gobo Module Assembly Removal" on
A
R
ODULE
SSEMBLY
EMOVAL
2
25