General Specifi Cations; Notice Special Requirements; Inspect/Prepare Installation Site; Clearances To Burner And Appliance - Beckett AFII 100 Manual

Afii burner with type ‘hlx’ air tube
Hide thumbs Also See for AFII 100:
Table of Contents

Advertisement

General Specifi cation
Table 1 – Burner Specifi cations
Capacity
'HLX' Heads
Firing rate:
Input: Min./Max - 56,000 /210,000 Btu/h
'FBX' Heads
Firing rate:
Input: Min./Max. - 56,000/189,000 Btu/h
Certifi cation/
UL certifi ed to comply with ANSI/UL296 &
Approvals
tested to CSA B140.0
Fuels
U. S No. 1 or No. 2 heating oil only (ASTM
Canada No. 1 stove oil or No. 2 furnace oil
Electrical
Power supply - 120 volts AC, 60 Hz, single
phase
Operating load - 5.8 Amps max
Motor - 1/7 hp, 3450 rpm, NEMA 48M
frame PSC rotation CCW when
facing shaft end
Ignition - Continuous duty solid-state igniter
Fuel pump
Outlet pressure - Note 1
Air tube
ATC code - See Table 2
Dimensions
Height (maximum) - 13 inches
(with cover)
Width (maximum) - 14 inches
Depth
Air tube diameter
*
Note 1. See appliance manufacturer's burner specifi cations for
recommended outlet pressure.
Table 2 – Air Tube Combinations (ATC) & Dimensions
ATC codes for usable air tube lengths dim. "A" (Figure 3)
3"
HLX30
HLX50
HLX30
HLX50
HLX30
HLX50
HLX30
HLX50
FBX30
FBX50
FBX30
FBX50
FBX30
FBX50
FBX30
FBX50
HB 6 slot
RWB 6104 BAFII R01
- 0.40 – 1.50 GPH
- 0.40 – 1.35 GPH
D396)
only
- 6-11/16 inches
- 3-1/2 inches
5"
7"
9"
HLX70
HLX90
HLX70
HLX90
HLX70
HLX90
HLX70
HLX90
FBX70
FBX90
FBX70
FBX90
FBX70
FBX90
FBX70
FBX90
HC 9 slot

Notice Special Requirements

For recommended installation practice in Canada,
refer to the latest version of CSA Standard B139 &
B140.
Concealed damage — If you discover damage to
the burner or controls during unpacking, notify the
carrier at once and fi le the appropriate claim.
When contacting Beckett for service information —
Please record the burner serial number (and have
available when calling or writing). You will fi nd the
serial number on the silver label located on the left
rear of the burner. Refer to Figure 1.

Inspect/Prepare Installation Site

Clearances to Burner and Appliance

Provide space around burner and appliance for
ease of service and maintenance. Check the mini-
mum clearances against those shown by the ap-
pliance manufacturer and by applicable building
codes.
ATC Code
Head
HB
AF2-6
0.4-0.85 gph
HC
AF2-9
HD
AF2-6
0.40-0.85 gph
HE
AF2-9
HFXS
FB0
0.40-0.65 gph
HGXS
FB3
0.55-0.85 gph
HHXS
FB4
HIXS
FB6
HD 6 slot
General Information
Firing rate range (gph)Min-Max
AFII 85
AFII 100
0.65-1.00 gph
N/A
0.65-1.00 gph
0.65-1.00 gph
N/A
0.65-1.00 gph
0.55-0.75 gph
0.55-1.10 gph
N/A
0.75-1.10 gph
N/A
0.85-1.15 gph
HE 9 slot
AFII 150
0.75-1.35 gph
0.75-1.50 gph
0.75-1.10 gph
0.75-1.35 gph
0.75-1.00 gph
0.85-1.20 gph
1.10-1.25 gph
1.15-1.35 gph
Page 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afii 150Fii 85Afii 85

Table of Contents