Installing or Replacing Server Components
Replacing a 2.5-inch Form-Factor NVMe PCIe SSD
OS-surprise removal is not supported. OS-informed hot-insertion and hot-removal are supported only
Note
with Cisco IMC release 2.0(13) and later and they depend on your OS version. See
by OS.
OS-informed hot-insertion and hot-removal must be enabled in the system BIOS. See
Note
Support in the System BIOS, page
For information about drive tray LEDs, see
Remove an existing NVMe SFF 2.5-inch SSD:
Step 1
a.
b.
c.
d.
Note
If this is the first time that NVMe SFF 2.5-inch SSDs are being installed in the server, you must install
PCIe riser version 2B and connect its cables before installing the drive. See
2B For NVMe SFF 2.5-Inch SSDs, page
Install a new NVMe SFF 2.5-inch SSD:
Step 2
a.
b.
c.
Observe the drive-tray LED and wait until it returns to solid green before accessing the drive:
Step 3
Cisco UCS C220 M4 Server Installation and Service Guide
3-18
Shut down the NVMe SFF 2.5-inch SSD to initiate an OS-informed removal. Use your operating
system interface to shut down the drive, and then observe the drive-tray LED:
Green—The drive is in use and functioning properly. Do not remove.
Green, blinking—the driver is unloading following a shutdown command. Do not remove.
Off—The drive is not in use and can be safely removed.
Press the release button on the face of the drive tray. See
Grasp and open the ejector lever and then pull the drive tray out of the slot.
If you are replacing an existing SSD, remove the four drive tray screws that secure the SSD to the
tray and then lift the SSD out of the tray.
Place a new SSD in the empty drive tray and replace the four drive tray screws.
With the ejector lever on the drive tray open, insert the drive tray into the empty drive bay.
Push the tray into the slot until it touches the backplane, and then close the ejector lever to lock the
drive in place.
Off—The drive is not in use.
Green, blinking—the driver is initializing following hot-plug insertion.
Green—The drive is in use and functioning properly.
3-17.
Front Panel LEDs, page
3-19.
Chapter 3
Maintaining the Server
Table 3-4
Enabling Hot-Plug
3-2.
Figure
3-8.
Installing PCIe Riser Version
for support
OL-32473-01