YOKOGAWA 7556 User Manual page 88

Digital resistance meter
Table of Contents

Advertisement

10.2 Commands
Command
READ Group
:READ?
RECall Group
:RECall?
:RECall:DATA[:ASCii]? Queries the measured data that are stored (ASCII format).
:RECall:DATA:BINary? Queries the measured data that are stored (binary format).
:RECall:RESult?
:RECall[:STATe]
SELFtest Group
:SELFtest:KEY
:SELFtest:LED
:SELFtest:HANDler
STATus Group
:STATus?
:STATus:CONDition?
:STATus:EESE
:STATus:EESR?
:STATus:ERRor?
:STATus:FILTer<x>
:STATus:QENable
:STATus:QMESsage
:STATus:SPOLl?
STORe Group
:STORe?
:STORe:COUNt
:STORe:POINts?
:STORe[:STATe]
TRIGger Group
:TRIGger?
:TRIGger:DELay
:TRIGger:EDGE
:TRIGger:MODE
Common Command Group
*CLS
*ESE
*ESR?
*IDN?
*LRN?
*OPC
*OPC?
*OPT?
*PSC
*RST
*SRE
*STB?
*TRG
*TST?
*WAI
10-14
Function
Queries the measured data.
Queries all settings related to the recalling of the measure data.
Queries the statistics related to the stored measured data.
Sets the measured data recall state (ON/OFF) or queries the current setting.
Executes the panel key test.
Executes the LED test.
Executes the handler interface output test.
Queries all settings related to the communication status.
Queries the status register.
Sets the extended event enable register or queries the current setting.
Queries the extended event register and clears the register.
Queries the error code and message information (beginning of the error queue).
Sets the transition filter or queries the current setting.
Sets whether or not to store messages other than errors in the error queue or queries the current setting.
Sets whether or not to attach message information to the response to the ":STATus:ERRor?" query or
queries the current setting.
Executes serial polling (dedicated command for RS-232).
Queries all settings related to the storing of the measured data.
Sets the number of data points to store or queries the current setting.
Queries the number of data points that are stored.
Sets the measured data store state (ON/OFF) or queries the current setting.
Queries all settings related to the trigger.
Sets the trigger delay or queries the current setting.
Sets the trigger edge or queries the current setting.
Sets the trigger mode or queries the current setting.
Clears the standard event register, extended event register, and error queue.
Sets the standard event enable register or queries the current setting.
Queries the standard event register and clears the register.
Queries the instrument model.
Queries current group settings.
Sets an OPC event upon the completion of the specified overlap command.
Creates a response upon the completion of the specified overlap command.
Queries the installed options.
Sets whether or not to clear the registers at power up or queries the current setting.
Initializes the settings.
Sets the service request enable register or queries the current setting.
Queries the status byte register.
Executes a manual trigger.
Performs a self-test and queries the result.
Holds the subsequent command until the completion of the specified overlap operation.
Page
10-25
10-26
10-26
10-27
10-27
10-28
10-28
10-28
10-28
10-29
10-29
10-29
10-29
10-30
10-30
10-30
10-30
10-30
10-30
10-30
10-31
10-31
10-32
10-32
10-32
10-32
10-33
10-33
10-34
10-34
10-34
10-34
10-34
10-34
10-34
10-34
10-35
10-35
10-35
10-35
10-35
IM 755601-01E

Advertisement

Table of Contents
loading

Table of Contents