4.4.6.3 Alarm Delay

When an alarm occurs, for example because measurement was not possible due to lack of
light, it will not be output immediately. Instead, the sensor holds and displays the last normal
measurement value until the number of times set here has been reached. When the number
of times set here has been exceeded, the alarm output (OUT3) will be turned ON. The analog
and the digital output will be turned ON according to the setting for analog output at alarm and
the setting for digital output at alarm, respectively.
NOTE
This function is useful if you do not require an alarm output as soon as the
surface of measured objects changes.
Setting range
0 to 65534
65535
70
SEN TRONIC
AG
Produkte, Support und Service
5x
or
to change the setting
Sets the number of measurement attempts to be made before an alarm
is output.
Function
0 (OFF) to 65534 times
Holds the last measurement value before the