Lubrication monitor controller. for controlling three pumps, each with one- to three -
line skf single line centralized lubrication systems (120 pages)
Page 1
Installation, operation and maintenance manual Ecomag Linear Actuator Read this manual before installing, operating or maintaining this actuator. Failure to follow safety precautions and instructions could cause actuator failure and result in serious injury, death or property damage.
The actuator may be destroyed if it is over- The feed speed is a function of the load! loaded! The ECOMAG can be loaded with push forces (ECO 2/4/6/8) or pull and push forces (ECO 3/5/7/9). The ECOMAG linear actuator "push version"...
Technical Instructions Linear drive Ecomag Installation and startup 3.1 Scope of delivery The ECOMAG actuator system comprises the following: Control unit Actuator and Control device 3.2 Installation The linear actuator must only be installed over the two fork heads. The load must act...
Technical Instructions Linear drive Ecomag Fastening the control unit externally The control unit must be installed at the installation slots provided (see Fig. 4), and must be installed so that it is free from mechanical forces and vibra- tions. Tightening torque: 1.7 – 2 Nm Fig.
Page 6
Technical Instructions Linear drive Ecomag Connecting / disconnecting the actuator cable on the control unit Motor connections that are not occupied on Connect the actuator cable in the direction of the arrow (see Fig. 7). the control unit are sealed at the factory. The Note: Observe the plug number.
The EHE handswitch is used to actuate one ishes, or it no longer works under load, it must or more ECOMAG linear actuators. A control be uninstalled immediately and taken out of panel is provided on the front foil of each use.
Technical Instructions Linear drive Ecomag 4.3 "Emergency lowering" in the event of a power failure (option) If the power fails, the actuators can be moved to their lower terminal position. If the "EMERGENCY lowering" features a patient safety function in the event of a...
Page 9
Technical Instructions Linear drive Ecomag Usage The emergency lowering mechanism must not be treated with oil, grease or any other lubri- cating substance, since this can lead to it be- coming dangerously easy to move! It must be ensured that no objects can hinder the lowering action.
The actuator has been designed for intermittent operation (see label). If a higher duty cycle is used, please contact the Magnetic factory. Thermofuse The ECOMAG linear actuator is fitted with a thermofuse. The thermoswitch integrated into the motor switches the actuator off if the temperature becomes excessive. 5.2 Care...
Technical Instructions Linear drive Ecomag 5.5 Technical data See brochure 530D, 2400 and the type designation on the label. 5.6 Troubleshooting Fault Cause Remedy Actuator(s) Control unit Plug in the mains cable. not working not plugged in Poor connector contact...
Need help?
Do you have a question about the Ecomag and is the answer not in the manual?