Open Window Function - Stanley Argon Built In ARBI100 Installation And Operating Instructions Manual

Table of Contents

Advertisement

1.
Press the Timer Setting button and the
remote screen will be as shown in Fig 9
with the temperature setting flashing.
2.
Adjust the temperature setting by pressing
the Adjust + and Adjust - buttons.
3.
Press the Shift Key to enter the time
parameters for Monday (1). - see Fig 10.
4.
Select the hour to be set (0-24) by pressing
the Adjust + and Adjust - buttons until the
desired hour is shown on the screen (see Fig
11- 8am shown).
5.
To select the operational mode, press the
Shift Key to select one of the following:
Heat & Flame Picture
6.
When finished setting the times for Monday,
press the Timer Setting button to enter the
time parameters for Tuesday (2).
7.
Repeat steps 4 & 5 for Tuesday and when
set press the Timer Setting button to enter
the next day.
8.
When the settings are complete for Sunday
(7), press the Timer Setting button to exit the
programmer settings.
To transfer the programmer settings to the unit,
press the Timer button on the remote control twice
and to set the unit to timed operation, press the
Timer button again so the Timer Icon appears on the
remote control screen (see Fig 12).

Open Window Function

The Open Window function when selected will
ensure that the heating function on the unit turns off
in a situation where a window in the room in which
the unit is fitted is left open.
After the Open Window function is turned on, the
unit firstly detects if the heating function is turned on.
If it is turned on, the program will save the current
ambient temperature value and detects the ambient
temperature change once every 12 minutes. When
the decrease in the ambient temperature detected
within 30 minutes exceeds 4°C, the program will
deem that the window is open and stop heating, and
the Open Window indicator on the unit will flash
rapidly. After it has stopped heating for 70 minutes,
the unit starts to detect if the window is closed, and
the Open Window indicator flashes slowly. The heat-
ing function will then operate on half heat for 6 min-
utes every 30 minutes. If the temperature rise is
more than 2°C, the window is considered closed and
the Open Window indicator stops flashing.
To turn on the Open Window function, press the
Open Window Function button and the Open
Window indicator will be display on the remote con-
trol screen (see Fig 13). Press the Open Window
Function button again to turn off.
Flame Picture
OFF Mode
Fig 10
Fig 11
Fig 12
Fig 13