Change battery

When installed batteries are going flat, lamp flashes 7 days before and alarm sounds (Ding dong sound like school bell). In this
case, replace all batteries with new one. Password or touch key (Card/Key tag) will not change even after replacing the batteries.
Product life span cannot be guaranteed if used batteries are used together with new one. It is required to use
quality alkaline battery. When using rechargeable battery, product can cause malfunction.
Please check battery polarity (+/-). Polarity reversal may cause malfunction. Consumer is liable for any damage
Caution
caused by faulty battery and make sure to use quality alkaline battery only.
Unlock a door with emergency battery
Unlock a door using password
Contact 9V battery to emergency socket → Press
Unlock a door using touch key or card/key tag
Contact 9V battery to emergency socket and place touch key (Card/Key tag) on external input pad to unlock a door.

Fault diagnosis and troubleshooting

Symptoms
Cannot remember password
Password input failure
(5 attempts)
Door is not automatically locked
button is not working
External button sound is not working
and lamp is not flashing
Product speicifications
The number of touch keys (Cards/Key tags)
Basic items
The number of remote controller to be registered
The number of fingerprints to be registered
Power supply
Emergency power source (Do not have polarity)
When batteries are completely flat after long term travel, the emergency power supply function
allows safe unlocking of a door. Purchase DC9V alkaline battery, contact it to emergency socket
on outdoor body and apply password or touch key (Card/Key tag).
Make sure that battery is properly contacted with emergency socket when using
this function. (External emergency power supply socket does not have polarity).
Location of external emergency power supply socket may differ according to
Caution
the product model.
button and enter password → Press
- Open a door using touch key (Card/Key tag) and register new password.
(number-dedicated models excluded)
- All functions are not available for 1 minute after failure of 5th attempt.
Wait for 1 minute and set new password or touch key (Card/Key tag).
- Check if auto locking function is enabled
- If other functions are not working, check if batteries are properly inserted.
If batteries are flat, replace them with new batteries.
- Check if there is any liquid leakage on battery case or product and if so,
wipe out contact area with a dry cloth.
Type
Use password
to be registered
Thickness of door
Power source
(Applied model with touch key and card/key tag)
Troubleshooting
Up to 50 (Applied models with touch key and card/key tag)
Up to 15 (Applied models with remote controller)
Up to 200 (Applied models with the input of the fingerprints)
6V (AA Size 1.5V Alkaline Battery X 4EA)
9V square alkaline battery (Purchase separately)
button to unlock
Specification
3 ~ 19 digits
35 ~ 50 mm