Instruction Sheet - Zvc404-Exp & Zvc406-Exp Zone Valve Control - Taco SR501 Wiring Manual

Zone controls, switching relays/ with powerport options and expandable to 20 zones, zone valve controls/with powerport options and expandable to 20 zones, plug-in powerport cards, add-on power controls, fan controls
Table of Contents

Advertisement

Wiring
Diagram
WHITE
120 VAC
24 VAC
INPUT
BLACK
WHITE
120 VAC
24 VAC
INPUT
BLACK
Installation of
Optional System
and/or DHW Circulator
END
N/O COM N/C
SWITCH
B
PUMP
SYSTEM
CIRCULATOR
DHW
120 VAC
CIRCULATOR
(See Note)
NEUTRAL
HOT
Operation/External Diagnostics:
heat, the appropriate zone valve is energized and the yellow light goes
on. When the zone valve is fully open, the red light goes on and ener-
gizes the end switch relays. The green light should always be on, indi-
cating that power is connected.
Priority Operation: When zone 6 is switched to the priority setting
and is actuated, all other zones will stop operation until zone 6 is sat-
isfied. When zone 6 is not switched to priority, all zones will operate
independently. Note: When a circulator is used on the priority zone
instead of a zone valve, jumper 3 and 4 of the priority zone.
Mode Operation: When the mode switch is set to NORMAL, both end
switch relays will be energized if any zone is in operation. When the
mode switch is set to RESET, the end switch relay "A" will only be ener-
gized when the priority zone is in operation. The end switch relay "B"
will be energized when any zone is in operation
Power Input: Connect 120 volt ac power input to leads on trans-
former. Neutral to white wire. Hot to black wire.
Expansion Connections: Set the expansion switch to MASTER on the
zone valve control that has the designated priority zone or is utilizing
the PowerPort options. Set all other daisy chained controls to SLAVE.
Connect thermostat wire (18-22 gauge) between terminals 1, 2, 3, 4 on
the master control to the corresponding 1, 2, 3, 4 on the SLAVE control(s).
Controls may be daisy chained up to 20 zones using any combination
of Switching Relay -EXP or Zone Valve -EXP controls.
Warning: Wiring connections must be made in accordance with all applicable electrical codes. Use copper wire only. Failure to follow this instruction can result in personal injury or death and/or property
damage. 10-18 gauge wire recommended for 120 VAC connections with 9 in.lbs. max torque, 12-22 gauge wire for thermostat connections with 9 in.lbs. max torque, and 12-22 gauge wire for 24 VAC source with
5 in.lbs. max torque.
Do it Once. Do it Right.
TACO, INC., 1160 Cranston Street, Cranston, RI 02920
TACO (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3.
Visit our web site at: http://www.taco-hvac.com
ZVC404-EXP & ZVC406-EXP Zone Valve Control
POWER
CONTROLS
SLAVE
MASTER
MODE
RESET
NORMAL
END
SWITCH
N/O COM
N/C
B
ZONE 6 RELAY
PUMP
DRY
CONTACTS
TO CIRCULATOR
TO CIRCULATOR
OR BOILER
OR BOILER
END
AQUASTAT RELAY
AQUASTAT RELAY
SWITCH
A
BOILER
T T
BOILER
When any thermostat calls for
Instruction Sheet
THERMOSTAT
24 VAC
PLUG-IN
CARDS
1 2 3 4
T
T
T
T
ZONE 1
ZONE 2
EXPANSION
SIX ZONE ZONE VALVE CONTOL
WITH OPTIONAL PRIORITY
ZONE 1
ZONE 2
END
SWITCH
1 2 3 4
1 2 3 4
A
BOILER
JUMPER
3 & 4
2 WIRE ZONE VALVE
3 WIRE ZONE VALVE
(NO END SWITCH)
The Taco Connection: Combine the reliability of the Taco Zone Valves,
Priority Zoning Circulators, Thermostats, and the "00" family of circula-
tors with the advanced features of the Taco Zone Controls to achieve
total system integration. No matter the application, Taco now provides
the products to maximize system performance while simplifying both
installation and service.
Specifications:
PRODUCT
NUMBER
NUMBER
OF ZONES
ZVC404-EXP 4 with Priority
ZVC406-EXP 6 with Priority
Zone Valve Controls are relay type DPDT and have a single phase motor rating per zone
All
1
of
hp (5A) @ 120 VAC.
6
Features:
External Indicator Lights
Plug-In PowerPort Cards
Switchable Priority
Simplified Wiring
Add-On Power Controls
Works with 2, 3, or 4-Wire
Zone Valves
UL Approved
Fuse Protected
100% Factory Tested
Telephone: (401) 942-8000
FAX: (401) 942-2360.
Telephone: 905/564-9422.
THERMOSTAT
THERMOSTAT
T
T
T
T
T
T
T
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZVC 406-EXP
ZONE 3
ZONE 4
ZONE 5
1 2 3 4
1 2 3 4
1 2 3 4
MOTOR
END
1
SWITCH
2
3
TACO
4 WIRE ZONE VALVE
(POWER OPEN, SELF CLOSING)
TRANSFORMER
MAX OUTPUT
VOLTAGE
AT 24 VAC
120 VAC Input
80 VA
120 VAC Input
80 VA
Isolated End Switch
Expandable to 20 Zones
Extra Set of Dry Contacts
Contractor Friendly PC
Universal Thermostat
Sturdy Screw Connections
Extended 3 Year Warranty
Made in the USA
FAX: 905/564-9436.
INDIRECT
WATER HEATER
AQUASTAT
OR THERMOSTAT
ZONE 6
PRIORITY
ON
T STAT 1
T
OFF
VALVE 1
T STAT 2
VALVE 2
T STAT 3
VALVE 3
T STAT 4
VALVE 4
T STAT 5
VALVE 5
T STAT 6
ZONE 6
VALVE 6
1 2 3 4
POWER ON
JUMPER
3 & 4
SEE NOTE
PRIORITY
ZONE
DIMENSIONS OF ENCLOSURE
WIDTH
HEIGHT
DEPTH
3
1
11
"
7
"
3"
4
2
3
1
11
"
7
"
3"
4
2
Board Layout
Compatibility
Printed in USA
Copyright 2000
TACO, Inc.
95