GENERAL SPECIFICATIONS :
Sensing : Average sensing.
Jaw opening size : 45 mm
Display : 3¾ digit LCD with a max. Reading of 3999.
Range Selection : Autorange selection
Polarity : Automatic negative polarity indication
Zero adjustment : Automatic
Over range indication : only the "OL" display
Low battery indication : The "
Auto Power Off : 30 minutes after stopping the switch or no push button, the meter automatically enter to
power off mode. Push button or run switch, auto power off disable.
Operating Temperature : 0 ~ 40°C, Humidity < 80% R.H.
Storage Temperature : -20 ~ 60°C, Humidity < 90% R.H.
Power Supply : 9V zinc ~ carbon battery.
Dimension : 225(H) x 77(W) x 45(D) mm
Weight : approx. 330g. (Including battery)
SAFETY :
Safety Standards : The meter is up to the standards of IEC 1010 double insulation, Pollution Degree 2, Overvoltage CAT II
ACCESSORIES :
Battery, Manual, Test leads(1 pair), Carrying Case.
AC CURRENT
Range
Accuracy
Resolution
±(2.5%rdg + 25dgts)
40
A
0.01 A
0.1
A
±(2.0%rdg + 20dgts)
400
A
1000 A
±(2.5%rdg + 25dgts)
0~800
1
A
±(5.5%rdg + 25dgts)
800~1000
Average sensing, calibrated to rms of sine wave
Overload protection : 1000Arms within 60 seconds.
AC VOLTAGE
Range
Accuracy
Resolution
±(3.0%rdg + 15dgts)
400 mV
0.1 mV
4
V
1
mV
±(1.0%rdg + 15dgts)
40
V
10 mV
400
V
100 mV
±(2.5%rdg + 15dgts)
750
V
1
V
Average sensing, calibrated to rms of sine wave
Overload protection : 1000V DC /750Vrms AC;
Impedance : 10M , More then 100M on 400mV scale
DIODE AND AUDIBLE CONTINUITY TEST
Description
Range
Display read approx.
Forward voltage of
diode.
Built-in buzzer sounds
if reisitance is less
than 90
Overload protection : 250V DC/250Vrms AC
®
An ISO 9001:2008 Company
Navin.com/D.drive/sandeep gupta/New catlog Dec 2011/KM 2783.cdr
®
3¾ DIGIT 1000A AC DUAL DISPLAY
" is display when the battery Voltage is below 7.2V.
- +
ELECTRICAL SPECIFICATIONS - KM 2783
Accuracies are ±(% of reading + digit) at 23°C ± 5°C Less than 70% R.H.
DC VOLTAGE
Frequency
Range
400 mV
50~60Hz
4
40
400
50~60Hz
1000 V
Overload protection : 1000V DC/750Vrms AC
Impedance : 10M , More then 100M on
Frequency
RESISTANCE
Range
50~400Hz
400
4
40
50~100Hz
400 k
4
40 M
Overload protection : 250V DC/250Vrms AC
Test condition
Forward DC current
approx. 0.4mA
Reversed DC Voltage
Approx. 1.5V
Open circuit voltage
approx. 0.5V
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022 -24156638,
Email : kusam_meco@vsnl.net,
DIGITAL CLAMP METER
Accuracy
Resolution
0.1 mV
V
1
mV
±(0.5%rdg + 7dgts)
V
10 mV
V
100 mV
±(0.8%rdg + 7dgts)
1
V
400mV scale
Accuracy
Resolution
±(1.8%rdg + 20dgts)
0.1
k
1
k
10
±(1.2%rdg + 20dgts)
100
M
1
k
±(2.0%rdg + 20dgts)
10 k
All Specifications are subject to change without prior notice
Tel. : 022-241224540, 24181649,
15 FUNCTIONS 34 RANGES
Model KM 2783
Preliminary Data
CAPACITANCE
Range
Resolution
10
pF
±(3.5%rdg + 30dgts)
40
nF
100 pF
400 nF
4
F
±(2.5%rdg + 25dgts)
1
nF
40
F
10
nF
100
F
±(5.0%rdg + 20dgts)
100 nF
Overload protection : 250V DC/250Vrms AC
FREQUENCY
Range
Resolution
10
Hz
0.01 Hz
100
Hz
0.1
Hz
1000 Hz
1
Hz
±(0.5%rdg + 15dgts)
10
kHz
10
Hz
100 kHz
100 Hz
1000 kHz
1
kHz
10
MHz
10 kHz
Overload protection : 250V DC/250Vrms AC
Sensitivity : Range of input voltage : 1.5V~1 0V,
if input voltage over range,
need adjust
DUTY CYCLE
0.1% ~99.9%
Fax : 022 - 24149659
Website : www.kusamelectrical.com
Accuracy
Accuracy

Advertisement

loading
Need help?

Need help?

Do you have a question about the KM 2783 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kusam-meco KM 2783

  • Page 1 G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct.: 022 -24156638, Tel. : 022-241224540, 24181649, Fax : 022 - 24149659 Email : kusam_meco@vsnl.net, Website : www.kusamelectrical.com An ISO 9001:2008 Company Navin.com/D.drive/sandeep gupta/New catlog Dec 2011/KM 2783.cdr...
  • Page 2 DIGITAL DUAL DISPLAY AC CLAMPMETER MODEL - KM 2783 KM 2783 °C 400A/ 1000A AUTO DH>2sec POWER OFF SELECT RANGE HzDuty AUTO 999.9 G 17,Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. T+V Hz Sales Direct : (022) 24156638...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS TAKE MEASUREMENT CAREFULLY AND YOU’LL SPARE YOUR METER AND YOURSELF, SOME PAIN Nearly every electrical engineer has a hand held Title Page digital clamp meter (Tongtester). We sometimes take them for granted, until we damage them or “burn Safety Information ........
  • Page 4: Safety Information

    This LCD Auto Range & Auto Power off Digital AC 7. Ensure that the test leads and probes are in good condition with no damage to the clamp multimeter is a portable, 3 3/4-digit insulation. multimeter. It is ideally suited for field, laboratory, shop and home applications.
  • Page 5: General Specifications

    2. GENERAL SPECIFICATIONS 3. ELECTRICAL SPECIFICATIONS Accuracies are ± (% of reading + number in last Display : 3¾ digit LCD with a max. reading digits ) at 23 ± 5°C, 75%RH. of 3999. DC Voltage Range control : Auto / Manual range control. Range Accuracy Resolution...
  • Page 6 Resistance Duty cycle : 0.1%~99.9% Range Accuracy Resolution Temperature (NiCr-NiSi sensor) 1.8% rdg + 20 dgts 400 Ù 0.1 Ù Range Accuracy* Resolution kÙ Ù 3°C + 2 40 kÙ 10 Ù 1°C -20~150°C 1.2% rdg + 20 dgts 400 kÙ 100 Ù...
  • Page 7 AC voltage or DC Voltage test. 4. RANGE key : Press the key to select manual mode, press it again to change the range. Press the key for KM 2783 more than 2 seconds to go back to auto range mode. Hz/Duty &...
  • Page 8: Measuring Instruction

    3. MEASURING INSTRUCTION Resistance measurement 1) Connect the black test lead to “COM” socket DC Voltage measurement and red test lead to the “ ” socket. 1) Connect black test lead to “COM” 2) Set the selector switch to desired “O” position, socket and red test lead to the “...
  • Page 9 Frequency measurement Temperature measurement 1) Connect the black test lead to “COM” socket 1) Connect the black test lead of the sensor to and red test lead to the “ ” socket. “COM” socket and the red test lead to the “ ”...
  • Page 10: Care And Maintenance

    2) Battery Replacement 1) Caring For Your Multimeter 1) Ensure the instrument is not connected to any KM 2783 Digital Multimeter is an example of external circuit. Set the selector switch to “OFF” superior design & craftsmanship. The following position and remove the test leads from the suggestions will help you care for the multimeter terminals.
  • Page 11: Test Certificate

    MUMBAI WARRANTY TEST CERTIFICATE Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 DIGITAL DUAL DISPLAY months) and begins from the date of despatch of goods.