42jt visisight series photoelectric clear object sensors with io-link

Advertisement

Quick Links

42JT VisiSight™ Photoelectric Clear Object Sensors with IO-Link
Default Settings:
Output Mode: Dark Operate (Output ON when the light between
sensor and reflector is blocked)
Output Type: Auto PNP/NPN or IO-Link. In Auto PNP/NPN mode,
the sensor continuously monitors the load connection and
automatically configures the output to PNP or NPN.
Sensor User Interface
Yellow LED
LED Status
The table below provides LED status in the RUN mode. During
operation, the sensor is always in RUN mode, except when being
taught.
Auto PNP/NPN Operation
OFF
ON
Green
Flashing (6 Hz)
Flashing (1.5 Hz)
OFF
Yellow
ON
IO-Link Operation
OFF
Green
Flashing (1 Hz)
OFF
Yellow
ON

Installation Instructions

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
Pushbutton
Green LED
Power is OFF
Power is ON
Unstable light level (0.5 < margin < 2)
Output short circuit protection active
Output de-energized
Output energized
Power is OFF
Power is ON
Output de-energized
Output energized

General Specifications

Environmental
Certifications
cULus and CE Marked for all applicable directives
IP67, IP69K, ECOLAB 
Operating Environment
-20...+60° (-4...+140°) 
Operating Temperature [C (F)]
Storage Temperature [C (F)]
-20...+80° (-4...+179°)
Optical
Light Source
Visible red 660 nm
Sensing Range
0...2 m (0...6.6 ft)
Adjustments
Push button
Electrical
10...30V DC 
Voltage
Current Consumption
30 mA max.
Sensor Protection
Reverse polarity, short circuit protection
Outputs
Response Time
0.5 ms
Output Type
Auto NPN or PNP
Output Function
Selectable light operate or dark operate
Output Current
100 mA max.
Output Leakage Current
10 μA max.
Mechanical
Housing Material
ABS
Lens Material
PMMA
Cover Material
PMMA
Optional Accessories
Mounting brackets, cordsets
 See Connection Types table.
 ECOLAB on P4 and A2 models only
 UL: -20...+50°C (-4...122°F)
 UL: Class 2 source
Connection Types
Cat. No. Suffix
-A2
-P4
-F4
4-pin DC micro (M12) QD on 150 mm (6 in.) pigtail
-Y4
4-pin pico (M8) QD on 150 mm (6 in.) pigtail
42JT-C2LAT1-
Description
2 m cable (PUR)
Integral 4-pin pico (M8) QD

Advertisement

loading

Summary of Contents for Rockwell Automation 42JT-C2LAT1-A2

  • Page 1: Installation Instructions

    Installation Instructions 42JT VisiSight™ Photoelectric Clear Object Sensors with IO-Link IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. Default Settings: General Specifications Output Mode: Dark Operate (Output ON when the light between 42JT-C2LAT1- sensor and reflector is blocked) Environmental Output Type: Auto PNP/NPN or IO-Link. In Auto PNP/NPN mode, Certifications cULus and CE Marked for all applicable directives the sensor continuously monitors the load connection and...
  • Page 2 For installation convenience, Position the clearest target to be detected between the Rockwell Automation offers a wide range of mounting brackets sensor and the reflector. Press and release the button. (see the Accessories section for more details).
  • Page 3 Output Type Selection: Wiring Diagrams Auto PNP/NPN, Dedicated NPN, Dedicated PNP) The following diagrams show the quick-disconnect connector. The pin numbers correspond to male connectors on the sensor. The default setting is Auto PNP/NPN. This means the sensor monitors the load connection and automatically configures for Micro (M12) Male QD on Pigtail and the proper operation, namely PNP or NPN.
  • Page 4 R 25.4 (0.55) (0.73) (1.0) (1.3) 60-2619 VisiSight-compatible swivel/tilt mounting bracket Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page Publication 42JT-IN006A-EN-P—10000290639 Ver 02—December 2014 Copyright © 2014 Rockwell Automation, Inc. All rights reserved. Printed in Germany. 068-14550...

This manual is also suitable for:

42jt-c2lat1-p442jt-c2lat1-f442jt-c2lat1-y4