Table 19-1. Compensation Table For Static Ground Setup
Static Engine RPM
Rated RPM
-20
-40
-60
-80
-100
-120
NOTE: All values are approximate. Variations may be noticed due to engine and installation
specific influences.
Example: TSI0L-550-C, Maximum Rated RPM = 2600
Metered Fuel Pressure Limits = 15.0 - 16.5
If maximum static engine RPM = 2540, (-60 RPM) use Correction Factor .973
Metered Fuel Pressure Limits x Correction Factor = Corrected Metered
15.0 x .973 = 14.595 (Minimum Metered Pressure Limit) @ 2540 RPM
16.5 x .973 = 16.054 (Maximum Metered Pressure Limit) @ 2540 RPM
Metered Pressure Vs. RPM @ 70°F Fuel Temperature
Correction Factor
1
.991
.982
.973
.964
.955
.946
Pressure Limits
Post Maintenance
Corrected Metered Pressure
(Metered Pressure
x Correction Factor)