Page 1
NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL Manual Part Number: 5-06-4900-75-0 Manual File:027245 Rev. A 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com...
Page 2
Manual Part Number: Manual File: P a g e | II 5-06-4900-75-0 027245 Rev. A...
Table of Contents TABLE OF CONTENTS FOR YOUR SAFETY ANALYZER WARNINGS GENERAL CAUTIONS WELCOME 1 PRODUCT DESCRIPTION 1-07 1.1 GENERAL 1-07 2 PRODUCT COMPONENTS 2-08 2.1 BASE MODULE 2-08 2.2 COUPLER WITH FILTER 2-08 2.3 CALIBRATION BULB 2-08 2.4 BATTERY CLIPS 2-08 3 INSTRUCTION FOR USE 3-09...
Identifier Warnings • SAMPLE FILTER WARNING: The Mini ID contains a unique filter designed to significantly reduce the probability of oil contamination. Replace the brass oil filter of the instrument AS SOON AS OIL IS DETECTED IN THE SAMPLE HOSE. Failure to properly maintain and replace the oil filter may result in severe damage.
General Cautions • ALWAYS wear eye and skin protection when working with refrigerants. Escaping refrigerant vapors will present a freezing danger. • ALWAYS turn the compressor OFF before connecting the instrument to an air conditioning system. • ALWAYS inspect the sample hose before each use. Replace the hose if it appears cracked, frayed, obstructed or fouled with oil.
The Neutronics Mini ID is an economical instrument designed to provide a “PASS” or “FAIL” indication for R-1234yf Purity. The product will also indicate if an excess amount of non- condensable gas (air) is present in the system.
RODUCT OMPONENTS Base Module Coupler with Filter Calibration Bulb Battery Clips Manual Part Number: Manual File: P a g e 5-06-4900-75-0 027245 Rev. A...
NSTRUCTION FOR WARNING: Be sure to turn off the vehicle and let it rest for 3 minutes. Connect the power cable to the power port located on the bottom of the instrument. Connect the power clips to the 12 VDC battery source. Be sure to observe the correct polarity.
Excess Air/Fail The Mini ID is equipped with a unique filter located between the coupler and hose. This is a disposable filter designed to trap oil and sealant to prevent damage to the unit. Remove and inspect the filter for oil etc.
APPENDICES Specifications REFRIGERANT DETECTED: R-1234yf PASS/FAIL PURITY: 12 VDC POWER: Oil Free Vapour Refrigerant SAMPLE SOURCE: MINIMUM INPUT PRESSURE: 1.38 Bar (20 Psig) 20.70 Bar (300 Psig) MAXIMUM INPUT PRESSURE: OPERATING TEMPERATURE: 50-113 F (10-45 UL, CE APPROVALS Manual Part Number: Manual File: P a g e | 11...
APPENDIX E – Warranty Neutronics Inc. warrants, subject to the terms listed below, that the goods will be free from defects in design, materials, and workmanship for a period of (1) one year from the date that the goods are shipped to the buyer.
Page 13
EXCEPT AS SPECIFICALLY SET FORTH AND LIMITED IN THIS PARAGRAPH, NEUTRONICS INC. MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES AS TO MERCHANTABILITY, OR AS TO THE FITNESS OF THE GOODS FOR ANY PARTICULAR USE OR PURPOSE, AND ANY WARRANTIES SET FORTH IN THIS PARAGRAPH ARE IN LIEU OF SUCH IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE OR PURPOSE.
Need help?
Do you have a question about the MINI ID and is the answer not in the manual?
Questions and answers