ascon e33 Operating Instructions Manual

ascon e33 Operating Instructions Manual

Digital electronic temperature controller with defrosting function

Advertisement

Quick Links

e33
DIGITAL ELECTRONIC
TEMPERATURE CONTROLLER
WITH DEFROSTING FUNCTION
OPERATING INSTRUCTIONS
Vr 01 (ENG) - 17/06 - cod.: ISTR-Me33ENG01
ASCON TECNOLOGIC S.r.l.
Viale Indipendenza 56, 27029 - VIGEVANO (PV) ITALY
Tel.: +39 0381 69871 - Fax: +39 0381 698730
http:\\www.ascontecnologic.com
info@ascontecnologic.com
PREFACE
D
D
This manual contains the information necessary for
the product to be installed correctly and also instruc-
tions for its maintenance and use; we therefore recom-
mend that the utmost attention is paid to the following
instructions and to save it
This document is the exclusive property of Ascon Tecnologic
S.r.l. which forbids any reproduction and divulgation, even
partially, of the document, unless expressly authorized.
Ascon Tecnologic S.r.l. reserves the right to make any formal
or functional changes at any moment and without any notice.
Ascon Tecnologic S.r.l. and its legal representatives do not
assume any responsibility for any damage to people, things
or animals deriving from violation, wrong or improper use or
in any case not in compliance with the instrument features.
Whenever a failure or a malfunction of the device
D
D
may cause dangerous situations for persons, thing
or animals, please remember that the plant has to be
equipped with additional electromechanical devices
which will guarantee safety.
Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 1
Index
1. Instrument description ............................................... 1
1.1
General description ........................................................... 1
1.2
Front panel pescription ..................................................... 2
2. Programming ............................................................... 2
2.1
Fast Set Point programming .............................................. 2
2.2
Standard mode parameters programming ........................ 2
2.3
Parameter protection using the password ......................... 3
2.4
programming level) ........................................................... 3
2.5
Reset parameters to default value .................................... 3
2.6
Keyboard lock function ...................................................... 3
3. Usage warnings ........................................................... 3
3.1
Admitted use ..................................................................... 3
4. Installation warnings ................................................... 4
4.1
Mechanical mounting ........................................................ 4
4.2
Electrical connections ....................................................... 4
5. Functions ..................................................................... 5
5.1
ON/Stand-by function ........................................................ 5
5.2
Normal, Economic and Turbo operation ............................ 5
5.3
Measure and display configuration ................................... 5
5.4
Digital input configuration .................................................. 6
5.5
Outputs and buzzer configuration ..................................... 6
5.6
Temperature control .......................................................... 7
5.7
5.8
Defrost control ................................................................... 8
5.9
Evaporator fans control ................................................... 10
5.10 Alarm functions ............................................................... 10
6. Accessories ............................................................... 12
6.1
7. Programmable parameters table .............................. 13
8. Problems, maintenance and warranty ..................... 16
8.1
Notifications .................................................................... 16
8.2
Cleaning .......................................................................... 16
8.3
Warranty and Repairs ..................................................... 16
8.4
Disposal .......................................................................... 16
9. Technical data ............................................................ 16
9.1
Electrical characteristics ................................................. 16
9.2
Mechanical characteristics .............................................. 16
9.3
Functional features ......................................................... 17
10. Instrument ordering code ......................................... 17
1.

INSTRUMENT DESCRIPTION

1.1

General description

The model e33 is a microprocessor based digital electronic
temperature controller that is typically used in cooling ap-
plications with ON/OFF temperature control and defrost
control at time intervals, by arrival at temperature or by
length of time of continuous compressor operation through
stopping the compressor, electric heating or hot gas/cycle
inversion.
The instrument has up to 3 relay outputs and up to 3 NTC
temperature probes inputs one of which can be config-
ured as digital input; it can also be equipped with a built-in
buzzer for alarms acoustic report.
/
/Aux ................................ 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the e33 and is the answer not in the manual?

Questions and answers

Summary of Contents for ascon e33

  • Page 1: Table Of Contents

    Whenever a failure or a malfunction of the device may cause dangerous situations for persons, thing or animals, please remember that the plant has to be equipped with additional electromechanical devices which will guarantee safety. Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 1...
  • Page 2: Front Panel Pescription

    : Indicates fan output status ON (on), OFF (off) the code of the selected parameter or inhibited (flashing). Pressing the keys, it is possible to select another parameter and change it as described. Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 2...
  • Page 3: Parameter Protection Using The Password

    (through which storage and distribution of chilled, frozen, deep-frozen/quick- will be possible to access the “protected” parameters). frozen food and ice cream”) with the following classification: Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 3...
  • Page 4: Installation Warnings

    Out 2: 8 (3) A 8 (4) A 10 A Res. Out 3: 5 (1) A 2 (1) A 2 A Gen. Use (12 A max. for removable connectors models) Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 4...
  • Page 5: Functions

    When used as a shop widow light (oFo = 3), Eco mode The instrument allows the measure calibration, which can selection is always associated with the Auxiliary Output turn be used to recalibrate the instrument according to applica- OFF function. Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 5...
  • Page 6: Digital Input Configuration

    NO in normal operation then closed when the alarm sounds; To control an alarm that cannot be silenced through a contact that is NO in normal operation then closed Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 6...
  • Page 7: Temperature Control

    HE output. The Buzzer sounds when a key pressed and when an In the event of a probe error, it is possible to set the instru- alarm is active. Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 7...
  • Page 8: Compressor Protection Function And Power-On Delay

    All these functions are disabled if the relative parameters are ddi time. set to OFF (oF). To force the instrument to perform a defrost cycle at each Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 8...
  • Page 9 Example: Defrost A ends due to reaching of temperature For correct functioning the instrument needs a first reference dtE, defrost B ends at the end of the ddE time as the Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 9...
  • Page 10: Evaporator Fans Control

    (compressor) is OFF. When the output is to be activated in alarm condition When ot output is OFF, it is possible to set the instrument so Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 10...
  • Page 11 APA it is not considered. AdA Temperature alarm exclusion time at the end of de- frost cycle (and, if programmed, after the draining) or after a continuous cycle. Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 11...
  • Page 12: Function Of Keys / And /Aux

    To use the device A01 it is necessary that the device or instru- ment are being supplied directly or through the key. Power supply Supply adapter 12 VDC AC supply For additional info, please have a look at the A01 instruction manual. Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 12...
  • Page 13: Programmable Parameters Table

    -99.9 ÷ +999°C/°F 10.0 Defrost start temperature -99.9 ÷ +999°C/°F -99.9 oF Function disabled; Delay start Defrost by dtF start temperature -1 ÷ -59 (s) ÷ 1 ÷ 99 (min) Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 13...
  • Page 14 -1 ÷ -59 (s) ÷ 1 ÷ 99 (min). oF Alarm memory disabled; Alarms memory on Alarm memory enabled; oF Function disabled; Temperature Alarms delay at power ON 2.00 -1 ÷ -59 (s) ÷ 1 ÷ 99 (min). Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 14...
  • Page 15 Set Point visibility with key fast procedure SP and SPE; Active SP; SP and SPH; SP, SPE and SPH. oF Function disabled; Password to Access Parameter functions 001 ÷ 999. Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 15...
  • Page 16: Problems, Maintenance And Warranty

    Pollution degree: 2; with the local standards in force on Operating temperature: 0 ÷ 50°C; waste disposal. Operating humidity: < 95 RH% with no condensation; Storage temperature: -25 ÷ +60°C. Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 16...
  • Page 17: Functional Features

    B = At package + “Butterfly” type brackets (standard) C = At package + gasket + screw type bracket e33 - f g h i j k i, k: RESERVED CODES; ll, mm: SPECIAL CODES Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 17...
  • Page 18 Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 18...
  • Page 19 Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 19...
  • Page 20 Ascon Tecnologic - e33 - OPERATING INSTRUCTIONS - PAG. 20...

Table of Contents