I N S T A L L A T I O N T I P S
Choose a mounting location capable of safely
supporting the full weight of the system when in
operation
Deliming of existing water using equipment is
recommended
Never use saddle valve for connection
Use 3/8" (9.5 mm) minimum water line
The water inlet must supply a minimum of
0.7 gpm (2.7 lpm)
Install vertically with cartridges hanging down and
allow 3" (76 mm) on all four sides of unit for
cover removal and service access
The product water tubing/piping and associated
fittings connecting the RO product outlet to the
equipment being serviced should be suitable for
use with high purity water
Refer to Installation, Operation & Maintenance
Manual for cartridge flushing and RO start-up
MRS-100-225 Series JA10.indd 1
MRS-100/100CC/225/225CC
M R S Rever s e O s m os i s S y s t e m
MRS-100 System:
EV9970-07*; EV9970-23**; EV9970-24***
MRS-100CC System:
EV9970-10*; EV9970-25**; EV9970-26***
MRS-225 System:
EV9970-08*; EV9970-27**; EV9970-28***
MRS-225CC System:
EV9970-09*; EV9970-29**; EV9970-30***
Pre-filter Kit: EV9795-81
6TO-BW Cart: EV9607-41
MR-100 Cart: EV9627-11
MR-225 Cart: EV9627-03
7CC-BW Cart: EV9627-05
P5 Cart: EV9109-08
- System shown with optional Pre-filter kit.
- System Voltages: *115 VAC/60Hz;
**230VAC/50Hz; ***240VAC/50Hz
O P E R A T I O N T I P S
Change filter cartridges on a regular 6-month
preventative maintenance program
Change RO cartridges on a regular 2-year
preventative maintenance program
Change cartridges when capacity is reached
Always flush the filter cartridge at time of
installation and cartridge change
Proper pre-treatment is required to control RO
Cartridge (membrane) scale formation and/or
fouling
- Raw water hardness in excess of 7 grains per
gallon (120 ppm) should be softened
- The raw water may contain particulates and
the use of a pre-filter is recommended
Contact EVERPURE Technical Service for
pre-treatment recommendations
B E N E F I T S
Improves equipment life and performance by
removing at least 90%+ of all dissolved solids
that cause scale build-up
Guards against taste and odor causing
contaminants while removing dirt, particulates
and dissolved minerals that can adversely affect
taste of water and beverages
Sanitary cartridge replacement is simple, quick
and clean–internal filter parts are never exposed
to handling or contamination
Wall mount design allows flexible installation
Reduces limescale build-up that can cause
excessive machine downtime and increased
maintenance costs–plus, scale reduction reduces
energy costs
"CC" models introduce a small amount of
hardness minerals back into the treated water
This controlled re-mineralization is desirable for
coffee and other applications that require some
hardness to achieve optimum results
A P P L I C A T I O N / S I Z I N G
Mineral Reduction System for foodservice
applications
Ideal for:
Flash steamers, conventional steamers,
cheese melters, combi-ovens and
coffee/espresso machines
Daily Production Rate:
MRS-100/100CC:
100 gpd (379 lpd) nominal
0.069 gpm (0.263 lpm) nominal
MRS-225/225CC:
225 gpd (852 lpd) nominal
0.156 gpm (0.591 lpm) nominal
For use in coffee, steam, reconstitution, ice and
multiple applications
1/11/10 10:01:53 AM