Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Syncrus G3 H and is the answer not in the manual?

Questions and answers

Summary of Contents for GNATUS Syncrus G3 H

  • Page 2: Presentation Of Manual

    PRESENTATION OF MANUAL INSTRUCTIONS FOR USE Technical Name: Dental Delivery Units Trade Name: Syncrus G3 H Delivery Unit Brand: GNATUS Manufacturer/ Distribuitor: GNATUS - EQUIPAMENTOS MÉDICO-ODONTOLÓGICOS LTDA. Rod. Abrão Assed , Km 53+450m - Cx. Postal 782 CEP 14097-500 Ribeirão Preto - S.P. - Brasil Fone +55 (16) 2102-5000 - Fax +55 (16) 2102-5001 C.N.P.J.
  • Page 3: Table Of Contents

    INDEX PRESENTATION OF MANUAL ................02 IDENTIFICATION OF EQUIPMENT ..............04 - Indication of Equipment ................04 - Principles and bases applied to the functioning of the product......04 - Description of Equipment ................05 MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION ..07 TECHNICAL SPECIFICATIONS ...............10 - Technical features of the Delivery Unit and its accessories ........10 - Electromagnetic emissions ................12 - Dimensions ....................16...
  • Page 4: Identification Of Equipment

    IDENTIFICATION OF EQUIPMENT Dear Customer Congratulations. You have made a good choice when you decided to buy a GNATUS QUALITY product comparable to the best products available in the World. This manual is a general presentation of your product and it will give you important details to help you to solve possible problems.
  • Page 5: Description Of Equipment

    To ensure safe operation of your equipment, use only assembly configurations (Chair, Equipment, Water Unit and Light reflector) provided by Reseller / Gnatus Authorized Service. ISO 9001 and ISO 13485 Quality system, ensuring that products are manufactured within standard procedures.
  • Page 6 IDENTIFICATION OF EQUIPMENT - Low cost of replacement. The cold light does not emit heat as conventional bulbs - Low temperature light polymerizes the resin without damaging the tooth pulp and prevents thermal expansion problems. - The forced ventilation system, transmitting unpleasant noise is not necessary. - High strength piece Conductive light removable tip, made of high strength polymer and easy maintenance - Suitable for single bleaching or up to three teeth.
  • Page 7: Modules, Accessories, Options And Materials Of Consumption

    MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION The contents of this page are of an informative nature, the equipment being able to differ from that illustrated. So, upon acquiring the product check the technical compatibilty between equipment, coupling and accessories. 15 15 15 01 - Bilateral Catcher 09 - Column arm...
  • Page 8 MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION...
  • Page 9 MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION 01. Terminals: Borden terminal (TB) Midwest Terminal (TM) Fiber Optic Terminal (FO) Electric micro motor Terminal (MME) 02. Curing Light + tip for 3 teeth (OPTI) Triple syringe with fully metal body or injected thermoplastic handle "optional heater set"...
  • Page 10: Technical Specifications

    TECHNICAL SPECIFICATIONS Technical features of the Delivery Unit and its accessories General Model Syncrus G3 H Delivery Unit Classification of Equipment as per ANVISA: Class II Classification of Equipment as per standard IEC 60601-1: Protection against Electric Shock - Type B and Class I Equipment (IEC 60601-1)
  • Page 11 TECHNICAL SPECIFICATIONS Specifications of Curring Light Power 5,2VA Light source 1 LED Active medium Semicondutor Led (InGaN) Wavelength 440nm - 460nm Timer 90 seconds Timer alarm Sound alarm with beep every 10 seconds and 4 beeps at the end of the cycle Activation Through the hand-piece button Light conductor...
  • Page 12: Electromagnetic Emissions

    TECHNICAL SPECIFICATIONS Pay attention while using this equipment together with other movable equipment, in order to avoid collisions. The materials used to produce the equipment are Biocompatible. Use of different cables, transducers and accessories from those specified may result in increased emissions or decreased immunity of the equipment. Electromagnetic Emissions Eletromagnetic emissions equipment...
  • Page 13 TECHNICAL SPECIFICATIONS Electromagnetic Emissions Guidelines and manufacturer's declaration - electromagnetic immunity equipment is made to be used in the electromagnetic environments specified below. The client or the user of the equipment must be sure that it is used in such environment. Immunity ABNT Test level Level of...
  • Page 14 TECHNICAL SPECIFICATIONS Electromagnetic Emissions Guidelines and manufacturer's declaration - electromagnetic immunity equipment is made to be used in the electromagnetic environments specified below. The client or the user of the equipment must be sure that it is used in such environment. Immunity ABNT test level Level of...
  • Page 15 TECHNICAL SPECIFICATIONS Electromagnetic Emissions Recommended distances between portable and mobile RF communication equipments and the equipment equipment is made to be used in an electromagnetic environment in which RF disturbances are controlled. The client or the user of the equipment may help preventing electromagnetic interference by keeping a minimal distance between mobile and portable RF communication equipment (transmitters) and the...
  • Page 16: Dimensions

    TECHNICAL SPECIFICATIONS Dimensions (mm)
  • Page 17: Packing Symbols

    TECHNICAL SPECIFICATIONS Packing symbols It determines the maximum Packing to be transported and quantity of boxes which can be / or stored avoiding humidity, stacked during transportation rains and wet floor. and storage “as per packaging”. The packing must be stored and Packing to be transported and / transported away from direct or stored with the harrows up.
  • Page 18 TECHNICAL SPECIFICATIONS Product symbols Authorized representative in It determines the initial position. the European Community It determines the work position I f d e t e r m i n e s t h e w o r k “1”. position ”2”.
  • Page 19: Standards Applied

    Maintenance of the equipment that can be found with the authorized Gnatus technician. - This equipment shall only be able to be unpacked and installed by a Gnatus authorized technician, under penalty of losing the warranty, as only (s)he has the information, suitable tools and training required to execute this task.
  • Page 20 OPERATION OF EQUIPMENT Positioning The arm has horizontal and vertical movements, with a pneumatic locking device. Maintaining the button “Arm break valve” pressed “item 12, page 07”, place the delivery unit in the desired position holding it by the handle, and release it to fasten it in this position. Terminal Drive Progressive pedal * (fig.01.) Fig.1...
  • Page 21 OPERATION OF EQUIPMENT Adjustment of Spray of “MME/FO high and low rotation terminals” The adjustment is made via the valves positioned under the box of the delivery unit (A). Turn it in a clockwise direction to reduce the spray and in a counterclockwise direction to increase it.
  • Page 22 OPERATION OF EQUIPMENT Curing Light Activation* Select application time, press time selection button (01), which values are: 10s (standard mode), 20s, 60s, 80s and 90s. To initiate a polymerization cycle, press the timer trigger (02), which generates a short beep every 10 seconds and a 4 beeps at the end of cycle.
  • Page 23 OPERATION OF EQUIPMENT Ultrasound Activation* Remove the ultrasound hand piece from the holder; Choose the appropriate insert for the wanted operation according to "Techniques and Applications"; Screw the chosen insert in the hand piece with the aid of clamping key (01) and a small grip; Actuate one of the pedals, progressive (Figure 1) * with water progressive locking system of the hand pieces (fig.2) * or chip-blower (fig.3) * (models of the pedals can vary according to the product configuration).
  • Page 24 OPERATION OF EQUIPMENT characteristics, will assure the maintenance of the best performances of the units, however, we recommended that the structure of the insert is not altered (limiting it or twisting it), in the same way the aging of an inserted drives to an alteration of its original characteristic, becoming it ineffective.
  • Page 25 OPERATION OF EQUIPMENT Equipment activation by the delivery unit panel* Description: Control Panel: The configuration of the equipment without the control 01 - X ray view operation panel does not interfere with product operation. 02 - Activation of the dental light 03 - Initial position 04 - Work position “1”...
  • Page 26 OPERATION OF EQUIPMENT When the “Emergency stop” (12) key is pressed, the LED will be on and all chair movements are interrupted until pressed again (12). It has 4 programmable working positions. To program, just position the chair and the reflector at the desired intensity and keep the chosen working position key pressed for 3 seconds, the chair will produce a long bip determining that the position was already programmed.
  • Page 27 IMPORTANT: Repeat this procedure before working day and after each patient. Bicarbonate Jet "Jet Hand"* Refer to Owner's Manual of Jet Hand (available for viewing and downloading via www. gnatus.com.br/manuais) * Optional...
  • Page 28: Precautions, Restrictions And Warnings

    - Transportation and storage temperature range: -12°C to 50°C. - Ambient temperature range recommended by Gnatus +10 ° C to +35 ° C. The Equipment maintains its condition of safety and efficacy, provided that it is maintained (stored) as mentioned in this instruction of use.
  • Page 29: Recommendations For The Dental Equipment Maintenance

    - The equipment should only be operated by duly enabled and trained technicians (Dental Surgeons, Capacitated Professionals) - If any maintenance should be required, only use services of the Gnatus Authorized Technical Assistance. - The equipment has been manufactured to handle both continuous and intermittent operation;...
  • Page 30: Precautions And Warnings During The "Cleaning And Disinfection" Of Equipment

    (failures, causes and solutions). If it is not possible to resolve the problem, turn off the equipment, remove the power supply cable from the socket and contact your representative (Gnatus). Precautions to be adopted against foreseeable or uncommon...
  • Page 31: Corrective And Preventive Maintenance And Preservation

    NOTE: The registration at the Ministry of Health of the “BactSpray” is executed separately from the product described in this manual, as the “BactSpray” is not manufactured by Gnatus. Disinfection Use clean and soft cloth dampened in alcohol 70% to disinfection of the equipment.
  • Page 32 CAUTION: Never expose the transducer covers to any type of oil because it can modify the structure of the material compromising it´s useful life. Bicarbonate Jet "Jet Hand" Refer to Owner's Manual of Jet Hand (available for viewing and downloading via www. gnatus.com.br/manuais)
  • Page 33: Preventive Maintenance

    For protecting your equipment, look for a Gnatus’ technical assistance for periodic reviews as preventive maintenances. Corrective Maintenance Gnatus states that the supplying of the circuits’ diagram, Part lists or any other information that permits the technical assistance by the user, can be requested, since previously agreed between the buyer and Gnatus.
  • Page 34: Unforeseen Events - Solution Of Problems

    UNFORESEEN EVENTS – SOLUTION OF PROBLEMS Upon coming across any problem in operation, follow the instructions below to check and repair the problem, and/or get in touch with your representative. Problem Probable cause Solution Delivery Unit -Handpiece is not working. - Compressor disconnected.
  • Page 35: Warranty Of Equipment

    UNFORESEEN EVENTS – SOLUTION OF PROBLEMS Upon coming across any problem in operation, follow the instructions below to check and repair the problem, and/or get in touch with your representative. Problem Probable cause Solution Ultrasound -Chair’s fuse burned -Turn off the chair from mains -The equipment doesn’...
  • Page 36: Final Considerations

    Among the care you have to take with your equipment, the most important is regarding of the spare parts replacement. To ensure the lifetime of your device, only replace original spare parts from Gnatus. They have the assurance of the standards and technical specifications required by the Gnatus representative.

Table of Contents