OPERATION
INSTALLING THE VALVE
Connect the valve to the hydraulic system as shown in
Figure 2.
OPERATING THE VALVE
Connect the valve to the tool using the illustration below
as a guide. Make sure the valve spool on the valve is
pushed OFF before connecting the valve to the hydraulic
system. Make sure the hydraulic system is OFF before
connecting the valve to the hydraulic system. Connect
the valve to the hydraulic system. Turn ON the hydraulic
system. Place the tool to be operated in its operating
position. Push the valve spool ON to begin operating the
tool. Push the valve spool OFF to stop operating the tool.
Turn the hydraulic system OFF before disconnecting the
valve.
Selector Screw
Tool Hoses
IN
72264 Valve
(PRESSURE)
00936 Adapter Fittings
Quick Disconnect Couplers
OUT
(RETURN)
Figure 2. Connecting the Valve
COLD WEATHER OPERATION
If the rod driver is to be used during cold weather, preheat
the hydraulic fluid at low engine speed. When using the
normally recommended fluids, fluid temperature should
be at or above 50 °F/10 °C (400 ssu/82 centistokes)
before use.