Disposizioni speciali: Misurazioni Representative in the Union: Patrick Vervier, Stanley Dubuis 17-19, rue Jules Berthonneau-BP 3406 41034 Blois Cedex, France. Vertreter in der Union/Représentant dans l’union/Representante en la Union/Rappresentante presso l’Unione Done at/Ort/Fait à/Dado en/Fatto a Stanley Hydraulic Tools, Milwaukie, Oregon USA...
REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN AUTHORIZED AND CERTIFIED DEALER. For the nearest certified dealer, call Stanley Infrastructure at (503) 659-5660 and ask for a Customer Service Representative. CH15 User Manual ◄ 3...
SAFE SYMBOLS Safety symbols and signal words, as shown below, are used to emphasize all operator, maintenance and repair actions which, if not strictly followed, could result in a life-threatening situation, bodily injury or damage to equipment. This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Place these precautions in the space provided on page 4. • Replace parts with parts recommended by STANLEY. The CH15 Hydraulic Chipping Hammer will provide safe • Check fastener tightness often and before each use.
“C” Sticker (5-GPM) “D” Sticker (8-GPM) 66654 Sound Power Level Sticker Stamping 28409 Composite Sticker 36112 Name Tag Sticker (CH1513101, CH1533101) D A N G E R D A N G E R FAILURE TO USE HYDRAULIC HOSE LABELED AND CERTI- DO NOT LIFT OR CARRY TOOL BY THE HOSES.
HOSE SAFETY TAGS To help ensure your safety, the following DANGER tags are attached to all hose purchased from STANLEY. DO NOT REMOVE THESE TAGS. If the information on a tag is illegible because of wear or damage, replace the tag immediately. A new tag may be obtained from your STANLEY Distributor.
HTMA / EHTMA REQUIREMENTS HTMA / EHTMA REQUIREMENTS HTMA TOOL TYPE HYDRAULIC SYSTEM REQUIREMENTS TYPE I TYPE II TYPE RR TYPE III 4-6 gpm 7-9 gpm 9-10.5 gpm 11-13 gpm Flow Range (15-23 lpm) (26-34 lpm) (34-40 lpm) (42-49 lpm) 1500 psi 1500 psi 1500 psi...
OPERATION PREPARATION PROCEDURES OPERATING PROCEDURES The tool, as shipped, has no special unpacking or 1. Observe all safety precautions. assembly requirements prior to usage. Inspection to 2. Move the hydraulic circuit control valve to the “ON” assure the tool was not damaged in shipping and does position.
Do not use the tool for applications for which it was • Always replace hoses, couplings and other parts not intended. with replacement parts recommended by STANLEY. Supply hoses must have a minimum working pressure rating of 2500 psi/172 bar. •...
TROUBLESHOOTING If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem. When diagnosing faults in operation of the tool, always make sure the hydraulic power source is supplying the correct hydraulic flow and pressure as listed in the table. Use a flowmeter known to be accurate. Check the flow with the hydraulic fluid temperature at least 80 °F/27 °C.
Nominal Flow ............................. 8 GPM/30 LPM Length..............................17 in./43 cm Weight ..............................16 lb./7.25 kg Tool Bit Models CH1513101, CH1533101 ..............580 in. Hex Shank Oval Collar Porting ..............................-8 SAE O-ring Couplers ..................HTMA/EHTMA Flush Face Type Male & Female Connect Size and Type ...................... 3/8 in. Male Pipe Adapter Hose Whips ................................
CH15 PARTS ILLUSTRATION Note: If you have a 5-GPM CH15 tool, the 3 parts that are required to make it a 5-GPM tool are no-longer available as of July 2015. If you need to replace any one of items 29, 31 or 32 you must purchase all 3 items to convert the tool to an 8-GPM tool, the tool will still work at 5-GPM if needed.
CH15 PARTS LIST ITEM DESCRIPTION MODEL DESIGNATIONS 28323 CE STICKER CH1513101 8 GPM MODEL 66654 SOUND PWR LEVEL STICKER CH1533101 8 GPM MODEL, UNDERWATER 73310 BODY 00016 O-RING * Δ 81110 VALVE SPOOL 81111 VALVE SLEEVE 81109 CUP SEAL Δ...
UNDERWATER TOOLS DEPTH GUIDELINE UNDERWATER MODELS ONLY Operation Overview Percussive Rotational Tools: Breakers, Tools: Grinders, DO NOT USE HYDRAULIC TOOLS UNDER- Hammer Drills and Saws, Chain Saws WATER THAT ARE NOT DESIGNATED AS Chipping Hammers AN “UNDERWATER” MODEL, OR THIS Max Depth: 1000' - WILL RESULT IN DAMAGE TO THE TOOL.
Page 20
Stanley Hydraulic Tools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www.stanleyhydraulics.com...