voltage shortage), the default value is 4, and the setting range is 0-7, hold
(UP) or
button (DOWN) shortly for selection.
C12 parameter definition table:
C12 value
0
1
2
3
4
5
6
7
C12 default value is 4, namely, controller minimum operating voltage (voltage
shortage value); when setting is 5, the default value plus 0.5V, when setting is 4, the
default value minus 0.5Vand so on.
After finishing C12 parameter setting, hold
current set values and enter C13 parameter setting interface.

C13 ABS brakes of the controller and parameters of anti-charge control Setting

Enter C13 parameter setting interface, C13 parameter bar flashes.
ELECTRIC BICYCLE METER KT—LCD6 Product User Manual
24V Controller
Default value-2V
Default value-1.5V
Default value-1V
Default value-0.5V
Default value 20V
Default value+0.5V
Default value+1V
Default value+1.5V
Minimum Voltage(V)
36VController
Default value-2V
Default
value-1.5V
Default value-1V
Default
value-0.5V
Default value
30V
Default
value+0.5V
Default value+1V
Default
value+1.5V
button (SW) shortly to save the
- 38 -
button
48VController
Default value-2V
Default
value-1.5V
Default value-1V
Default
value-0.5V
Default value
40V
Default
value+0.5V
Default value+1V
Default
value+1.5V

Hide quick links: