When C5 setting is 10, maximum current value is controller maximum operating
current value (ie, limit current value); when setting is 9, maximum current value divided by
1.10, when setting is 8, maximum current value divided by 1.15 and so on.
After finishing C5 parameter setting, hold
current set values and enter C6 parameter setting interface.
○
C6 Backlight Brightness Adjustment Setting
Enter C6 parameter setting interface after C5 parameter setting is finished, C6
parameter column flashes.
C6 is the meter backlight brightness adjustment setting, the default value is 3, and
setting range is 1-5, hold
selection.
ELECTRIC BICYCLE METER KT—LCD6 Product User Manual
C6 parameter setting interface
button (UP) or
Maximum current value÷1.33
Maximum current value÷1.25
Maximum current value÷1.20
Maximum current value÷1.15
Maximum current value÷1.10
Maximum current value
button (SW) shortly to save the
button (DOWN) shortly for