Download Print this page

Panduit TX6 PLUS Installation Instructions page 2

Utp jack modules

Advertisement

©Panduit Corp. 2011
9
T568B
Cable End 1
1
2
Cable End 2
2
1
3
See note 4.
1
Notes:
1. For specified performance, follow ANSI/NECA/BICSI-568-2006 installation guidelines.
2. Jack Modules can terminate 22-26 AWG solid or stranded IWC data cable with 0.062 (1.57 mm) maximum insulated conductor outside diameter.
3. Jack Modules may be re-terminated a minimum of 20 times.
4. On cable end 2 for A & B wiring and cable end 1 of A wiring, wrap the designated pairs around the proper center dividing post (A or B) and terminate in
the proper location.
5. For technical and performance information, consult Panduit Technical Support.
As with all Communication Components, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages
and Technical Support:
http://www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
T568A
Cable End 1
2
1
3
Cable End 2
2
1
3
REMOVAL STEPS
2
www.panduit.com
Page 2 of 2
10
11
12
13
3
E-mail:
techsupport@panduit.com
Phone:
866-405-6654
PN403L
CWST
EGJT