5. Using the appropriate screwdriver, remove the clips that secure the electric cord to
the unit.
6. Remove the four screws that affix the stainless steel cover of the UV-C lamp to the
Silvershine unit.
7. Leaving the sponge in place in the UV-C cavity, gently remove the lamp from the
ballast and replace with the new UV-C lamp.
8. Reassemble the UV-C cover, electric cord clips, and stainless steel cover on the
unit.
CPICDMOPINST
Electric cord
clips
Page - 18
SALES + SERVICE
(905) 829-2355
www.cpishine.com