Advertisement

UV Lamp is not on
No Heat
CPICDMOPINST
Lamp has burned out
Lamp ballast has no power
Fuse on control board has
blown
Fuse on control board has
blown
Faulty thermostat
Faulty element
Page - 12
Remove four screws on the shroud
housing the UV lamp, check that the
lamp has not burned out. Replace lamp
if necessary
Check for power to the lamp – check for
power to interior lamp ballast (behind
control panel, right side of
compartment– you must remove the
front panel for access), Replace lamp
ballast if necessary
Check for power to lamp ballast, check
fuse on control board behind the
controller (with panel off).
Check for power to heating element,
check fuse on control board (with panel
off)
Check thermostat control, mounted on
interior compartment (with front panel
off), ensure it is set 1/8
"HIGH" – replace thermostat, if
necessary
Replace heating element if necessary
With unit empty, run for 30 minutes,
pilot indicator on control panel should
"cycle" on and off