7.0 EXAMPLE SETTINGS

Suggested settings. Not all possible setting combinations are shown.
The ResponseONE CONFIG program is recommended for changing
setup parameters. See wiring diagrams for jumper settings.
7.1 FACTORY DEFAULT
RS-232
Enabled
RS-485
Disabled
Serial Output Format: ASCII
Output Interval
1000
Sample Count:
16
7.2 MINIMUM POWER
RS-232
Enabled
RS-485
Disabled
Serial Output Format: ASCII
Output Interval
1000
Sample Count:
16
7.3 HIGH WIND
Output Delay:
1000
Sample Count:
200
AVERAGE CURRENT DRAW AT 12V
Output
Output Format
Interval
5 minutes
SDI-12 (polled)
5 minutes
1 second
ASCII
1 second
ASCII Polled
5 minutes
1 second
NMEA
1 second
0.25 second
RMYT
1 second
Table Typical current draw per output format.

8.0 EMC COMPLIANCE

This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à Ia norme NMB-001 du Canada.
EN55011/CISPR 11, Group 1, Class B device.
Class B equipment is suitable for use in domestic establishments
and in establishments directly connected to a low voltage power
supply network which supplies buildings used for domestic
purposes.
Average
Sample
Baud Rate
Current Draw
Count
(bps)
(mA)
16
1200
4.5
100
1200
4.5
16
9600
8.4
100
38400
20.7
16
9600
5.8
16
4800
7.4
50
4800
12.4
16
9600
15.6
200
9600
34.2

9.0 WARRANTY

This product is warranted to be free of defects in materials and
construction for a period of 12 months from date of initial purchase.
Liability is limited to repair or replacement of the defective item. A copy
of the warranty policy may be obtained from R. M. Young Company.

10.0 CE COMPLIANCE

This product has been tested and complies with European
CE requirements for the EMC Directive. Please note that shielded
cable must be used.
Page 9
91000-90(B)