4.2.2 ORIENTATION USING BUILT-IN ELECTRONIC
COMPASS.
Note: Acclimate the ResponseONE to ambient
temperature at the installation site before calibrating.
Place ResponseONE sensor on mounting pipe, fully
seating it on the pipe and allowing for free rotation of
the sensor. Connect cable as indicated in APPENDIX
A and apply power to the system. (Refer to Fig 4.2.2)
With junction box cover removed, press and hold the
"CALIBRATE" button for 3 seconds; the indicator light
will blink rapidly to indicate that calibration mode is
active. Slowly rotate the sensor for 1-1/4 rotations. After
completing the rotations, press and hold the "CALIBRATE"
button again for 3 seconds; the indicator will double blink.
Within the next 60 seconds, tighten the mounting post band
clamp to secure the sensor. DO NOT OVER-TIGHTEN. At
this point, the compass will lock the direction of the sensor
and the ResponseONE will output correct wind direction
data; the indicator will continue to blink once per second.
Reattach J-Box cover and engage orientation ring as
shown in Fig 4.2.3 Tighten the orientation ring band clamp.
Important: Be sure to allow for magnetic declination in
your measurement. A declination value can be entered
using the ResponseONE CONFIG program or it can be
compensated in the data-logger program. Please note that
declination may change if the sensor is moved to a new
location. Accurate declination data can be obtained from
the following website:
http://www.ngdc.noaa.gov/geomag-web/#declination
CALIBRATE
BUTTON
Fig 4.2.2 Orientation of Wind Sensor Using Electronic Compass
Fig 4.2.3 Proper Engagement of Orientation Ring with Sensor

4.3 WIRING CONNECTIONS

The ResponseONE is supplied with RS-232, RS-485 and SDI-12
signal capability. Please select the signal type desired and refer to
the appropriate WIRING CONNECTIONS diagram in APPENDIX A
for connecting the ResponseONE to your serial device. Please note,
the ResponseONE is not equipped with analog outputs.

5.0 OPERATION

5.1 SERIAL OUTPUT FORMATS

The ResponseONE comes standard with the following serial output
formats:
Format/Protocol
ASCII Polled and Continuous
NMEA 0183 v3.0 Automatic
SDI-12 Polled
RMYT
ROTATE
1-1/4 TURNS
Detailed information about each protocol is in the following section.
If you wish to change settings from the factory default values shown
in Section 3, this is easily done using the ResponseONE CONFIG
program described in Section 6.0.
Page 3
SENSOR CLAMP
INDEX PIN IN NOTCH
ORIENTATION RING
Wiring Format
RS-232, RS-485
RS-232, RS-485
SDI-12
RS-485
91000-90(B)