State B
BitsS
function
Bits0
gross=0, net=1
Bits1
symbol:positive =0,negative =1
Bits2
overload(or lower zero)=1
Bits3
dynamic=1
Bits4
unit:lb=0, kg=1
Bits5
Constant 1
Bits6
Constant 0
State C
Bit2
Bit1
0
0
0
0
0
1
Bit 3
Bit 4
Bit 5
Bit 6
5.3 Serial interface reception command:
RS232COM serial interface can receive simple ASCII command.
Command word and role as follows:
Page 22 of 27
User Manual
Bit0
unit
0
Kg or lb
1
g
0
t
printing=1
Extend
display=1
Constant 1
Constant 0