Download Print this page

System Configuration; Name Of Each Part; Specifications - Omron FZ-DU Instruction Sheet

Usb switcher for fz series

Advertisement

FZ-DU
Model
USB Switcher for FZ Series
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet
primarily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your
convenience, keep the sheet at your disposal.
TRACEABILITY INFORMATION:
Importer in EU :
Manufacturer:
Omron Europe B.V.
Omron Corporation,
Wegalaan 67-69
Shiokoji Horikawa, Shimogyo-ku,
2132 JD Hoofddorp,
Kyoto 600-8530 JAPAN
The Netherlands
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
2010
© OMRON Corporation
All Rights Reserved.
PRECAUTIONS ON SAFETY
Please observe the following content.
·Do not use it in locations subject to explpsove or
flammable gases.
·Do not attempt to disassemble, repair, or modify the
Product.
·Do not impose voltage exceeding the rated voltage.
·When supplying power to the Sensor, make sure that the
polarity of the power is correct, and do not connect to an
AC power supply.
·When disposing of the USB Switcher ;treat it as
industrial
PRECAUTIONS FOR SAFE USE
Do not install the USB Switcher in the following
locations.
·Locations subject to direct sunlight.
·Locations where the relative humidity exceeds the range
of 35% to 85%.
·Locations subject to corrosive or flammable gases.
·Locations subject to direct vibration or shock.
·Locations subject to strong electromagnetic or electrical
fields.
·If you notice any abnormality in the USB Switcher, stop
using it immediately, turn OFF the power supply, and
contact your OMRON sales representative.
·Regulations and Standards
This product is compliant with the standards below:
EN Standards(European Standards), EN61326-1
Electromagnetic environment : Industrial
electromagnetic environment
(EN/IEC 61326-1 Table 2)
Also, the following condition is applied to the immunity
test of this product.
: If the level of disturbance of the video is that with
characters on the monitor are readable, the test is pass.
PRECAUTIONS FOR CORRECT USE
Observe the following precautions to prevent the product
from malfunctioning, becoming inoperable, or the
performance and/or the device from being adversely
affected:
■About installation features
·Ambient temperature outside the rating
·Rapid temperature fluctuations (causing condensation)
·Relative humidity outside the range of 35 to 85%
·Presence of corrosive or flammable gases
·Presence of dust, salt, or iron particles
·Direct vibration or shock
·Direct sunlight
·Water, oil, or chemical fumes or spray
·Strong magnetic or electric field
■Orientation of Product
Use only the same orientation as floor mounting for
installation of the product. Do not use any other
orientation for installation of the product.
■Dimensions
12
8
34
50
■About the installation
·Please do not install it on the equipment with a high
calorific value.
·Please adjust the ambient temperature of the
specification to 50℃ or less.
·Please never exceed 50℃ by setting up the compulsion
fan and the air conditioner when the ambient
temperature of the specification is near 50℃.
Control panel
Fan
■Noise immunity
·Please do not install it in the board where the
high-pressure installation is set up.
·Please separate from the power line by 200mm or more.
200mm or more
200mm or more
■About detaching the cable
Please turn off power when you detach the cable.
·Mounting
Please insert it straight with the part of the resin.
·Detaching
Please pull it out straight.
■Application
This unit is an option equipment only for the FZ series to
switch by using one USB input equipment (mouse etc.)
and one monitor and to operate two or more controllers
(4 or less).

■Specifications

(1)General specifications
Item
Specification
Power supply voltage
DC20.4 to 26.4V
Current consumption
MAX:200mA
Insulation resistance
20MΩmin. at 500V DC
Dielectric strength
1000V AC. 50/60 Hz for 1 min
Leakage current
1mA or less
Vibration resistance
10 to 150Hz: half-amplitude: 0.1mm
10 times each in X, Y, and Z directions for 8 min
Ambient temperature
0 to 50℃
Ambient humidity
Operation and storage: 35 to 85 %
(with no icing nor condensation)
Storage temperature
-5 to +55℃
Ambient environment
No corrosive gases
Degree of protection
IP20
Environmental condition
The indoor use
The high degree : up to 2000m.
IEC664 Pollution extent 2
Materials
Case:ABS/PC
Weight
Approx:500g
(2)Performance specifications
USB input interface
TypeA 1ch
USB output interface
TypeA 4ch
USB input interface
4ch(Analog RGB video)
USB output interface
1ch(Analog RGB video)
Channel switch
Channel switch button or
external signal
*It doesn't correspond to DDC of the monitor.
*The power supply capacity is 300mA or less.
*Please leave space about 500ms or more about the
channel switch.
*It is not likely to be able to connect it according to USB
mouse's kind etc.
(3)Accessories
Instruction sheet(this sheet)
Ferrite core···2
150
8
34
122.2
(UNIT:mm)

■System configuration

Controller
Controller
Controller
Controller
No.0
No.1
No.2
No.3
Monitor cable
VIDEO IN No.0
VIDEO IN No.1
VIDEO IN No.2
VIDEO IN No.3
USB OUT
VIDEO OUT
COM IN
24VDC
No.0
No.1
No.2
No.3
IN0 IN1
+
-
FZ-VM
■Terminal stand input
The monitor screen is
・ External instrument
output.
The channel can be
switched as a
programmable controller
etc.
・ Power supply input
DC24V is input.
FZ-M08
CH0
CH1
CH2
CH3
POWER
USB INPUT
REMOTE
MANUAL
■Mode switch
USB interface
·MANUAL
The switch of the channel is
possible by a channel switch
button.
·REMOTE
The switch of the channel is
possible by an external input.
■External input
Signal
Function
COM IN
24VDC
IN0
External switch
IN1
Common
COM IN
IN0 IN1
+
-
Relation between switch signal and channel.
External
Channel
Channel
Channel
Channel
signal
No.0
No.1
No.2
IN0
OFF
ON
OFF
IN1
OFF
OFF
ON
(2)Input specification
Circuit
COM IN
+
Input terminal
Performance
Input voltage
DC12 to 24V±10%
On current
2 to 15mA
On voltage
2V or less
Off current
0.1mA or less
Off voltage
10V or more
*COM IN Voltage:24V
Please do the twist to the electric wire to avoid the
inductive noise.
COM IN
24VDC
IN0 IN1
+
-
Please install an accessory ferrite core on the power
supply line. The installation position is a place separated
from the FZ-DU side terminal by approx 10mm.
Ferrite core
Approx 10mm
Terminal stand
Please roll the cable
once in the ferrite core.
Please install an accessory ferrite core in the mouse. The
installation position is a place separated from the FZ-DU
side connector by approx 10mm.
USB interface
USB INPUT
Ferrite core
Approx 10mm
USB input device
connection connector
Please roll the cable
once in the ferrite core.
■When you touch the terminal and
the connector area
Please do the electrification prevention with a list strap.
■Wiring to power supply terminal
USB cable
The screw of the terminal stand uses M3. Please use the
pressure terminal that fits the screw of M3.
Tightening torque:0.5 to 0.6N·m
Recommended parts
Maker
Model
Fork type
JST
V1.25-N3A
Round type
JST
V1.25-MS3

■Name of each part

(1)Front panel
CH0
CH1
CH2
POWER
REMOTE
MANUAL
①Power supply display LED
It lights to green in power supply ON.
②Channel display LED
LED of the selected channel lights to green.
③Channel switch button
The switch of the channel is possible.
④Mode switch
It is a switch that changes the operation mode.
Channel switch
It is possible to select it
MANUAL
with a front channel
switch button.
It is possible to select it by
an external input. It is not
REMOTE
possible to switch with a
front channel switch button.
⑤USB input device connection connector
The USB mouse are connected.(The power supply
capacity is 300mA or less.)
*It is not likely to be able to connect it according to
No.3
USB mouse's kind etc.
ON
ON
(2)Back panel
VIDEO IN No.0
VIDEO IN No.1
VIDEO IN No.2
USB OUT
VIDEO OUT
No.0
No.1
No.2
No.3
①For monitor input
The monitor cable is connected. It is possible to
connect it up to four.
Applicable cable: 15 Pin HD D-Sub Male/Female :
#4-40Screw cable(Both sides)
②For monitor output
FZ-VM is connected. The monitor screen of the
controller who has been selected is output.
③Terminal stand
When switching from the external instrument, it uses
it. Please set the cover of the attachment.
④For USB output
Four outputs or less to the FZ controller can be
connected.
Applicable cable: USB Type-A Male/Male cable
Suitability for Use
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer's application or use of the Product. At Buyer's request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer's application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
OMRON Corporation
Industrial Automation Company
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
s
D
Oct, 2 014
Size of recommended
electric wire
0.3 to 1.65mm
2
CH3
USB INPUT
Console operation
It operates it with the
equipment connected
with the USB input.
VIDEO IN No.3
COM IN
24VDC
IN0 IN1
+
-

Advertisement