replacement valve. A manometer capable of reading to
the nearest 0.1 wc-in will be required for this adjust-
ment
CAUTION: All gas conversion must be done by a
qualified service person in accordance with these
instructions and in compliance with all codes and
requirements. In Canada, gas conversion shall be
carried out in accordance with requirements of the
Provincial Authorities having jurisdiction and in
accordance with the requirements of the CAN/GGA-
B149.1 and .2 installation code.
START-UP
WARNING: Read and follow instructions carefully
when installing or servicing machine. Failure to do
so may result in damage to property or personal
injury.
1. Installation or servicing of gas appliances and
controls must only be performed by qualified
personnel. After installation or servicing, test the
manual valve, operating valves, pressure regula-
tion, and automatic shut-off valve for proper opera-
tion.
2. Install in a suitable dry location. Machine must be
located in an area properly protected from weather.
3. Shut off gas and electricity before starting installa-
tion or service. Turn back on to test or operate.
4. DO NOT connect machine before pressure testing
the gas piping. Damage to gas valve may result.
(9" - 14" W.C.P. or 1/2 PSIG)
5. DO NOT insert any object other than suitable pipe
or tubing in the inlet or outlet of the gas valve.
Internal damage may occur and result in a
hazardous condition.
6. DO NOT short the gas valve terminals.
7. DO NOT grip gas valve body with a pipe wrench or
vise. Damage may result causing gas leakage. Use
inlet or outlet bosses or a special body wrench.
8. DO NOT allow any flame to impinge on the
regulator vent tubing if supplied. It may clog and
cause gas valve malfunction.
9. DO NOT use the gas cock to adjust gas flow.
10. If main burner fails to shut off, turn off gas supply.
11. Keep all combustible materials away from gas
appliances. DO NOT allow lint or dust to collect in
burner area.
Landa ENG Dealer's Manual 9.801-510.0 - AV
12. Dials must only be operated by hand. Never use
pliers, wrenches or other tools to turn dials.
13. Leak test with a soap solution after installation or
service with the main burner on. Coat pipe and
tubing joints, gaskets, etc.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
If you do not follow these instructions exactly, a fire or
explosion may result, causing property damage,
personal injury or loss of life.
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
"FOR YOUR SAFETY
"WHAT TO DO IF YOU SMELL GAS"
Do not try to light any appliance.
Do not touch any electrical switch, do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your supplier, call the fire
dept.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not push
in or turn by hand, don't try to repair it; call a qualified
service technician. Forced or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service tech-
nician to inspect the appliance and to replace any part
of the control system and any gas control which has
been under water.
Operations