Length of
Pipe (ft.)
3/4"
1"
10
360
680
20
250
465
30
200
375
40
170
320
50
151
285
60
138
260
70
125
240
80
118
220
90
110
205
100
103
195
150
84
160
200
72
135
Maximum capacity of pipe in cubic feet/hr of natural gas
(Multiply values by 1000 to get nominal BTU/hr
capacity).

LP-Gas (Liquid Petroleum Gas or Propane)

LP-gas is gas compressed into liquid form for easy
transportation and storage. It is also known as propane
or bottle gas.
(Propane tanks are not supplied with this equipment.)
LP-gas is flammable, is always contained under
pressure and the liquid can freeze skin. Therefore, in
the interest of safety, it is important to understand the
basic facts about LP-gas and LP-gas containers.
Federal DOT (Department of Transportation) regula-
tions require periodic inspections and re-qualifications
of cylinders. DO NOT USE damaged or rusted
containers.
DO NOT store LP-gas containers indoors or in
enclosed areas. Do not expose LP-gas container to
heat. Always store with service valve closed and
plugged as required.
CAUTION: Use LP-gas containers in proper
position.
Most LP-gas pressure washer heaters are designed to
operate on LP-gas vapor only. Therefore, all LP-gas
containers designed for vapor service must be trans-
ported, installed and used in the proper position. Do not
transport, install or use a vertical cylinder in a horizontal
or upside down position. Proper care must be taken to
position a horizontal container in the correct position for
Iron Pipe Size
1 -1/4" 1- 1/2"
2"
1400
2100
3950
950
1460
2750
770
1180
2200
660
990
1900
580
900
1680
530
810
1520
490
750
1400
460
690
1300
430
650
1220
400
620
1150
325
500
950
280
430
800
Landa ENG Dealer's Manual 9.801-510.0 - AV
vapor withdrawal. Liquid LP-gas could enter the system
designed for vapor only, possibly creating a hazardous
condition.
Always use a POL plug installed on a POL valve or a
dust cap on an ACME/Type 1 valve when transporting
or storing disconnected containers (full or empty).
Check for leaks after connecting. Apply approved leak
detector solution to connection, turn off all burners and
pilots and open service valve. Leaks will be detected by
the growth of bubbles. If bubbles grow, tighten or repair
the connection as needed. Repeat leak test until
problem is corrected.
Check all tank and the line connections periodically to
be sure they are tight. When testing for leaks, use
approved leak detector solution — not matches.
Improved Regulation: The second stage regulator
receives a relatively uniform pressure from the first
stage regulator. This helps the second stage regulator
to maintain appliance pressure at a nearly constant 11"
W.C.

Filling the LP-Gas Container

Only qualified persons should fill your LP-gas
containers.
CAUTION: Overfilling is hazardous!
DO NOT allow your LP-gas container to be overfilled.
Stop filling when liquid appears at the fixed level gauge.
Bleed off excess propane in a safe area. Most LP-gas
containers are equipped with a fixed liquid level gauge
which contacts the liquid level at 80% of container
capacity, allowing 20% for expansion. LP-gas
containers not equipped with a fixed liquid level gauge
can only be filled by weight.
In cold climates, in order to keep vaporization of LP-gas
at the highest level, keep the fuel levels above 50%.

Propane Tank Disposal

Propane tanks present a real danger in the waste
stream, so it is essential to properly dispose of old
tanks so they do not injure you or sanitation workers.
The best way to dispose of unused propane tanks is by
calling a propane company to pick it up. Propane tanks
are not picked up by garbage collectors, and improper
disposal is illegal in some areas. If a propane tank is
unfit for service, one should contact a propane
company.