DURKOPP ADLER 559 Instruction Manual page 241

Sewing automat
Table of Contents

Advertisement

Available languages

Available languages

Error
2301
2302
2352
2353
2355
2356
2362
2911
-
2914
3100
-
3103
3107
3221
-
3222
66
Info/Description
· Step motor Z-axis
timeout reference
· Cable to the reference switch
faulty
·Reference switch defective
· Step motor Z-axis
Current supply fault
· Step motor Z-axis
blocked
· Encoder cable not
connected/defective
· Encoder defective
· Step motor Z-axis
excess current
· Step motor Z-axis defective
· Control defective
· Step motor Z-axis
excess voltage
· Too high mains voltage
· Step motor Z-axis
overcharge
· Step motor Z-axis
blocked/moves too heavy
· Step motor Z-axis defective
· Control defective
· Step motor Z-axis
excess temperature
· Step motor Z-axis
moves too heavy
· Step motor Z-axis defective
· Control defective
· Step motor Z-axis
IDMA Autoincrement
· Malfunction
· Step motor fault
· Internal fault
· Machine voltage fault
· Short-term mains voltage dip
· Machine temperature
· Ventilation openings
closed
· Ventilation grids soiled
· Too high ambient temperature
· Machine thread tension
regulator
· Internal fault
Remedy
· Replace the cable
· Replace the reference switch
· Eliminate the blocking
· Check/Replace the encoder cable
· Replace step motor Z-axis
· Replace step motor Z-axis
· Replace the control
· Check the mains voltage
· Eliminate the blocking/rough
running
· Replace step motor Z-axis
· Replace the control
· Eliminate the rough running
· Replace step motor Z-axis
· Replace the control
· Switch the machine off
and on again
· Switch the machine off
again.
· Software update
· Inform DA-Service
· Check the mains voltage and
stabilize, if necessary
· Check the ventilation openings
· Clean the ventilation grids
· Let the machine cool down
· Switch the machine off
again
· Software update
· Inform DA-Service
and on
and on

Advertisement

Chapters

Table of Contents
loading

Table of Contents