Error
2155
2156
2162
2201
2202
2252
2253
2255
2256
2262
Info/Description
· Step motor X-axis
overcharge
· Step motor X-axis
blocked/moves too heavy
· Step motor X-axis
defective
· Control defective
· Step motor X-axis
excess temperature
· Step motor X-axis
moves too heavy
· Step motor X-axis
defective
· Control defective
· Step motor X-axis
IDMA Autoincrement
· Malfunction
· Step motor Y-axis
timeout reference
· Cable to the reference switch
faulty
· Reference switch defective
· Step motor Y-axis
Current supply fault
· Step motor Y-axis
blocked
· Encoder cable not
connected/defective
· Encoder defective
· Step motor Y-axis
excess current
· Step motor Y-axis defective
· Control defective
· Step motor Y-axis
excess voltage
· Too high mains voltage
· Step motor Y-axis
overcharge
· Step motor Y-axis
blocked/moves too heavy
· Step motor Y-axis defective
· Control defective
· Step motor Y-axis
excess temperature
· Step motor Y-axis
blocked/moves too heavy
· Step motor Y-axis defective
Control defective
· Step motor Y-axis
IDMA Autoincrement
·Malfunction
Remedy
· Eliminate the blocking/rough
running
· Replace step motor X-axis
· Replace the control
· Eliminate rough running
· Replace step motor X-axis
· Replace the control
· Switch the machine off and on
again
· Replace the cable
· Replace the reference switch
· Eliminate the blocking
· Check /
Replace the encoder cable
· Replace step motor Y-axis
· Replace step motor Y-axis
· Replace the control
· Check the mains voltage
· Eliminate the blocking/rough
running
· Replace step motor Y-axis
· Replace the control
· Eliminate the blocking/rough
running
· Replace step motor Y-axis
· Replace the control
· Switch the machine off
and on again
3