ROGRAMMING UIDE Important Notice No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of merchantability or fitness for any particular purpose. We are not liable for any errors contained herein nor for incidental or consequential damages in connection with furnishing, performance or use of this material.
ROGRAMMING UIDE Settings and Programming Scan selected barcodes in this manual to affect setup and programming of your handheld imaging barcode scanner. Decoding options and interface protocols can be tailored to a specific application. Setup parameters are stored in non-volatile memory in the scanner and are retained even when power is off.
UIDE Interface Mode Interface Switch The S302D imaging barcode scanner supports USB virtual COM, USB-HID and RS232. The USB cable supports both USB virtual COM and USB-HID modes. Please install the virtual COM port driver before using USB Virtual COM.
ROGRAMMING UIDE Baud Rate Baud rate is the number of bits of data transmitted per second. Set the imager's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form. 1200BPS 2400BPS 4800BPS...
ROGRAMMING UIDE 57600BPS 115200BPS (Default) Word Format: Parity, Data bits, Stop bits A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. Parity: checks character bit patterns for validity;...
Page 12
ROGRAMMING UIDE Even 7,1 Even 7,2 Even 8,1 Odd 7, 1 Odd 7, 2 Odd 8, 1 Advanced imaging barcode scanner...
ROGRAMMING UIDE User Preferences System Settings Scan this barcode to return all parameters to the default values. Set All Defaults Scan this barcode to enable AUX Scanner. Aux Scanner Enable Scan this barcode to show scanner version. Show Version Advanced imaging barcode scanner...
ROGRAMMING UIDE Spanish Keyboard To enable Spanish keyboard layout in USB HID interface, please scan all 3 barcodes below to complete the setting. Enable Spanish keyboard Code 128 Code Page: Binary Code 39 Code Page: Binary English Keyboard To return to English keyboard from Spanish keyboard scan the following barcode. Enable English keyboard Advanced imaging barcode scanner...
ROGRAMMING UIDE Beeper-Good Read To enable or disable beeper, scan the following barcodes. Beeper Volume-Good Read To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume barcode. Low Volume Medium Volume High Volume Advanced imaging barcode scanner...
ROGRAMMING UIDE Beep During Good Decode Scan a barcode below to select the duration of the beep signal after a good decode. Normal Short LED Illumination To enable or disable LED illumination, scan the following barcodes. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE LED-Good Read To enable or disable LED indicator after a good read, scan the following barcodes. (Default) Number Of Beep-Good Read Scan a barcode below to select the number of the beep signal to sound after a good decode.
ROGRAMMING UIDE Good Read Delay Scan a barcode below to set the minimum amount of time before the imager can read another barcode after a good read. No Delay 200ms (Default) 500ms 2000ms *Specified *To set your own length for the good read delay, scan the “Specified” barcode, then set the delay by scanning digits from the Appendix, then scan “Save”.
ROGRAMMING UIDE Same Code Delay Scan a barcode below to set the minimum amount of time before the imager can read the same barcode a second time. No Delay 500ms (Default) 2000ms Advanced imaging barcode scanner...
ROGRAMMING UIDE Scan Mode Scan a barcode below to set the imager to trigger manually or automatic scanning until a barcode has been read. Manual Trigger Mode (Default) Auto Scan Mode Manual Mode Timeout To a set timeout for the imager’s trigger when using Manual Trigger, scan the following “Timeout”...
ROGRAMMING UIDE Centering Windows To change the field of view of your imager, scan “On” to enable the feature, and then scan one of the following barcodes to change the top, bottom, left, or right of the centering window. (Default) Left of centering window 40% Right of centering window 60% Top of centering window 40%...
ROGRAMMING UIDE Ship Image To ship the image stored in the imager memory, scan the follow barcode. JPG/BMP No Read Enable this function to transmit a No Read message when a code can not be read. (Default) Image Reverse Enable this function to allow the imager to read barcodes that are inverted. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE Data Redundant This function sets the imager to read the barcode multiple times before accepting data. Data Redundant Check = Off (Default) Data Redundant Check = 1 Data Redundant Check = 2 Data Redundant Check = 3 Advanced imaging barcode scanner...
ROGRAMMING UIDE Data Editing Prefix / Suffix Prefix and Suffix are additional characters that can be sent before and after the scanned data. Prefix Suffix To set up Prefix/Suffix: Prefix Set Up Flow Ex. If we wish to add “3” as prefix for all barcode type, then follow procedure as below, Scanning [prefix] to enter setup.
ROGRAMMING UIDE Suffix Set Up Flow Ex. If we wish to add “36” as suffix for all barcode type, then follow procedure as below, Scanning [suffix] to enter setup. Then we select barcode by scanning code ID of all barcode which is [9] [9], then we scan [3] [3] as 3 of ASCII HEX and [3] [6] as 6. Before we save, we scan command to setup terminator.
ROGRAMMING UIDE Data Format To change the output format, scan the following barcodes. Data followed by <Enter> (Default) No message after data Data followed by <Enter> + new line Data followed by new line Data followed by TAB Advanced imaging barcode scanner...
ROGRAMMING UIDE Cap Locks To change the capital lock preferences, scan the following barcodes. Cap Locks On Cap Locks Off Advanced imaging barcode scanner...
ROGRAMMING UIDE Symbologies Introduction This chapter describes symbology features and provides the programming barcodes for selecting these features. The device is shipped with the settings shown in the Symbology Default Table. If the default values suit requirements, programming is not necessary. There are two ways to change a parameter value: ...
ROGRAMMING UIDE Codabar Codabar Enable/Disable To set Codabar to its default settings, scan Default; to enable or disable Codabar, scan On or Off. Default (Default) Codabar Stop/Start Characters Stop/Start Characters set the leading and trailing ends of the barcode. Don’t Transmit (Default) Transmit Advanced imaging barcode scanner...
ROGRAMMING UIDE Codabar Check Characters Scan a barcode below to set the Codabar check character preferences. No Check Character (Default) Validate But Don’t Transmit Validate And Transmit Codabar Message Length Please see Message Length on setting the message length. Maximum (Default: 60) Minimum (Default: 4)
ROGRAMMING UIDE Code 39 Code 39 Enable/Disable To set Code 39 to its default settings, scan Default; to enable or disable Code 39, scan On or Off. Default (Default) Code 39 Full ASCII Conversion Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set.
ROGRAMMING UIDE Code 39 Append To set the imager to append Code 39 data before transmitting to the host, scan the appropriate barcode below. (Default) Code 39 Check Characters Scan a barcode below to set the Code 39 check character preferences. No Check Character (Default) Validate But Don’t Transmit...
ROGRAMMING UIDE Code 39 Start/Stop Characters Start/Stop Characters set the leading and trailing ends of the barcode. Transmit Don’t Transmit (Default) Code 32 Pharmaceutical To enable/ disable Code 39 Pharmaceutical, scan the appropriate barcode below. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE Interleaved 2 of 5 Interleaved 2 of 5 Enable/Disable To set Interleaved 2 of 5 to its default settings, scan Default; to enable or disable Interleaved 2 of 5, scan On or Off. Default (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE Interleaved 2 of 5 Check Characters Scan a barcode below to set the Interleaved 2 of 5 check character preferences. No Check Character (Default) Validate But Don’t Transmit Validate And Transmit Interleaved 2 of 5 Message Length Please see Message Length on setting the message length.
ROGRAMMING UIDE NEC 25 NEC 25 Enable/Disable To set NEC 25 to its default settings, scan Default; to enable or disable NEC 25, scan On or Off. Default (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE NEC 25 Check Characters Scan a barcode below to set the NEC 25 check character preferences. No Check Character (Default) Validate But Don’t Transmit Validate And Transmit Advanced imaging barcode scanner...
ROGRAMMING UIDE Straight 2 of 5 Industrial Straight 2 of 5 Industrial Enable/Disable To set Straight 2 of 5 Industrial to its default settings, scan Default; to enable or disable Straight 2 of 5 Industrial, scan On or Off. Default (Default) Straight 2 of 5 Message Length Please see...
ROGRAMMING UIDE Matrix 2 of 5 Matrix 2 of 5 Enable/Disable To set Matrix 2 of 5 to its default settings, scan Default; to enable or disable Matrix 2 of 5, scan On or Off. Default (Default) Matrix 2 of 5 Message Length Please see Message Length on setting the message length.
ROGRAMMING UIDE Code 11 Code 11 Enable/Disable To set Code 11 to its default settings, scan Default; to enable or disable Code 11, scan On or Off. Default (Default) Code 11 Check Characters Scan a barcode below to set the Code 11 check character preferences. 2 Check Digit (Default) 1 Check Digit...
ROGRAMMING UIDE Code 128 Code 128 Enable/Disable To set Code 128 to its default settings, scan Default; to enable or disable Code 128, scan On or Off. Default (Default) Code 128 Message Length Please see Message Length on setting the message length. Maximum (Default: 80) Minimum...
ROGRAMMING UIDE Code 93 Code 93 Enable/Disable To set Code 93 to its default settings, scan Default; to enable or disable Code 93, scan On or Off. Default (Default) Code 93 Message Length Please see Message Length on setting the message length. Maximum (Default: 80) Minimum...
ROGRAMMING UIDE MSI Enable/Disable To set MSI to its default settings, scan Default; to enable or disable MSI, scan On or Off. Default (Default) MSI Check Characters Scan a barcode below to set the MSI check character preferences. Validate Type 10, Transmit Validate Type 10, Don’t Transmit (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE Telepen Telepen Enable/Disable To set Telepen to its default settings, scan Default; to enable or disable Telepen, scan On or Off. Default (Default) Telepen Output Scan a barcode below to set the Telepen Output preferences. Original Output AIM Output (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC/EAN/JAN UPC-A Enable/Disable To set UPC-A to its default settings, scan Default; to enable or disable UPC-A, scan On or Off. Default (Default) UPC-A Check Characters Scan a barcode below to set the UPC-A check character preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC-A Number System Scan a barcode below to set the UPC-A Number System preferences. (Default) UPC-A 2 Digit Scan a barcode below to set the UPC-A 2 Digit preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC-A 5 Digit Scan a barcode below to set the UPC-A 5 Digit preferences. (Default) UPC-A Addenda Required Scan a barcode below to set the UPC-A Addenda Required preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC-A Addenda Separator Scan a barcode below to set the UPC-A Addenda Separator preferences. (Default) UPC-E0 To set UPC-E0 to its default settings, scan Default; to enable or disable UPC-E0, scan On or Off. Default (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC-E1 Scan a barcode below to set the UPC-E1 preferences. (Default) UPC-E0 Expand Scan a barcode below to set the UPC-E0 Expand preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC-E0 Check Digit Scan a barcode below to set the UPC-E0 Check Digit preferences. (Default) UPC-E0 Number System Scan a barcode below to set the UPC-E0 Number System preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC-E0 Addenda 2 Digit Scan a barcode below to set the UPC-E0 Addenda 2 Digit preferences. (Default) UPC-E0 Addenda 5 Digit Scan a barcode below to set the UPC-E0 Addenda 5 Digit preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC-E0 Addenda Required Scan a barcode below to set the UPC-A Addenda Required preferences. Not Required (Default) Required UPC-E0 Addenda Separator Scan a barcode below to set the UPC-A Addenda Separator preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE EAN/JAN-13 To set EAN/JAN-13 to its default settings, scan Default; to enable or disable EAN/JAN-13, scan On or Off. Default (Default) EAN/JAN-13 Check Digit Scan a barcode below to set the EAN/JAN-13 Check Digit preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE EAN/JAN-13 Addenda Required Scan a barcode below to set the UPC-A Addenda Required preferences. Not Required (Default) Required EAN/JAN-13 Addenda Separator Scan a barcode below to set the UPC-A Addenda Separator preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE IBSN Translate Scan a barcode below to set the IBSN Translate preferences. (Default) EAN-8 To set EAN -8 to its default settings, scan Default; to enable or disable EAN-8, scan On or Off. Default (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE EAN-8 Check Digit Scan a barcode below to set the EAN-8 Check Digit preferences. (Default) EAN-8 Check Digit Addenda Scan a barcode below to set the EAN-8 Check Digit Addenda preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE EAN-8 Addenda Required Scan a barcode below to set the EAN-8 Addenda Required preferences. Not Required (Default) Required EAN-8 Addenda Separator Scan a barcode below to set the EAN-8 Addenda Separator preferences. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE UPC-A/EAN-13 Extend Coupon Code Scan a barcode below to set the UPC-A/EAN-13 Extend Coupon Code preferences. (Default) EAN.UCC Emulation Scan a barcode below to set the EAN.UCC Emulation preferences. (Default) EAN.UCC-128 Emulation RSS. Emulation Advanced imaging barcode scanner...
ROGRAMMING UIDE Postal Code Note: For best performance when reading a postal code, please enable only one postal symbology and disable the rest. To enable or disable a postal code, please scan the following barcode first to enter programming mode, then scan the On or Off barcode for your postal code. Postal Code China Postal Code To set China Postal Code to its default settings, scan Default;...
ROGRAMMING UIDE China Postal Code Message Length Please see Message Length on setting the message length. Minimum (Default: 4) Maximum (Default: 80) Han Xin Code To set Han Xin Code to its default settings, scan Default; to enable or disable Han Xin Code, scan On or Off.
ROGRAMMING UIDE Han Xin Code Message Length Please see Message Length on setting the message length. Minimum (Default: 1) Maximum (Default: 7873) Korean Postal Code To set Korean Postal Code to its default settings, scan Default; to enable or disable Korean Postal Code, scan On or Off.
ROGRAMMING UIDE Korean Postal Code Message Length Please see Message Length on setting the message length. Minimum (Default: 4) Maximum (Default: 48) PostNet Scan a barcode below to enable or disable PostNet. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE PostNet Check Digit Scan a barcode below to set the PostNet Check Digit preferences. Not Transmit (Default) Transmit Planet Code Scan a barcode below to enable or disable Planet Code. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE Planet Code Check Digit Scan a barcode below to set the Planet Code Check Digit preferences. Don’t Transmit (Default) Transmit British Post Scan a barcode below to enable or disable British Post code. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE Japanese Post Scan a barcode below to enable or disable Japanese Post code. (Default) Canadian Post Scan a barcode below to enable or disable Canadian Post code. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE Kix Post Scan a barcode below to enable or disable Kix Post code. (Default) Australian Post Scan a barcode below to enable or disable Australian Post code. (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE RSS (Reduced Space Symbology) The variants of RSS are RSS 14, RSS Expanded, and RSS Limited. The limited and expanded versions have stacked variants. Scan the appropriate barcode below to enable or disable each variant of RSS. RSS-14 To set RSS-14 to its default settings, scan Default;...
ROGRAMMING UIDE RSS-Limited Code To set RSS-Limited Code to its default settings, scan Default; to enable or disable RSS- Limited, scan On or Off. Default (Default) Advanced imaging barcode scanner...
ROGRAMMING UIDE RSS-Expanded Code To set RSS-Expanded Code to its default settings, scan Default; to enable or disable RSS- Expanded, scan On or Off. Default (Default) RSS-Expanded Code Message Length Please see Message Length on setting the message length. Maximum Minimum Advanced imaging barcode scanner...
ROGRAMMING UIDE 2D Symbologies PDF417 To set PDF417 to its default settings, scan Default; to enable or disable PDF417, scan On or Off. Default (Default) PDF417 Message Length Please see Message Length on setting the message length. Maximum (Default: 2750) Minimum (Default: 1) Advanced imaging barcode scanner...
ROGRAMMING UIDE Micro PDF417 To set Micro PDF417 to its default settings, scan Default; to enable or disable Micro PDF417, scan On or Off. Default (Default) Micro PDF417 Message Length Please see Message Length on setting the message length. Maximum (Default: 366) Minimum (Default: 1)
ROGRAMMING UIDE Codablock F To set Codablock F to its default settings, scan Default; to enable or disable Codablock F, scan On or Off. Default (Default) Codablock F Message Length Please see Message Length on setting the message length. Maximum (Default: 2048) Minimum (Default: 1)
ROGRAMMING UIDE Aztec To set Aztec to its default settings, scan Default; to enable or disable Aztec, scan On or Off. Default (Default) Aztec Message Length Please see Message Length on setting the message length. Maximum (Default: 3832) Minimum (Default: 1) Advanced imaging barcode scanner...
ROGRAMMING UIDE Maxicode To set Maxicode to its default settings, scan Default; to enable or disable Maxicode, scan On or Off. Default Maxicode Message Length Please see Message Length on setting the message length. Maximum (Default: 150) Minimum (Default: 1) Advanced imaging barcode scanner...
ROGRAMMING UIDE Data Matrix To set Data Matrix to its default settings, scan Default; to enable or disable Data Matrix, scan On or Off. Default (Default) Data Matrix Message Length Please see Message Length on setting the message length. Maximum (Default: 3116) Minimum (Default: 1)
ROGRAMMING UIDE QR Code To set QR Code to its default settings, scan Default; to enable or disable QR Code, scan On or Off. Default (Default) QR Code Message Length Please see Message Length on setting the message length. Maximum (Default: 7089) Minimum (Default: 1)
ROGRAMMING UIDE QR Code Advanced Data Setting To change the GS1 Send Keystroke for FNC1 from default [F8] to "$", scan barcode below. Send $ Advanced imaging barcode scanner...
ROGRAMMING UIDE Maintenance Cleaning the scan window is the only maintenance required. A dirty window may affect scanning accuracy. Never use any abrasive material or solvents on the window. Do not spray water or other cleaning liquids directly onto the window. Remove dirt by wiping gently with a damp cloth or tissue moistened with water and/or ammonia.
ROGRAMMING UIDE Appendix B Code ID Table Symbology Code ID Code ID in HEX Code 128 GS1-128(UCC/EAN-128) AIM-128 EAN-8 EAN-13 ISSN ISBN UPC-E UPC-A Interleaved 2 of 5 ITF-6 ITF-14 Matrix 2 of 5 Industrial 2 of 5 Standard 2 of 5 Code 39 Codabar Code 93...
ROGRAMMING UIDE Appendix C Sample Barcodes Canada Post 4-State 01,K1A0B1,7010, Japan Post 4-State 80342716666 US POSTNET 8034271888 Australian Post 8034271999 Dutch Post - Royal TPG Post KIX 4-State 1231FZ13XHS USPS PLANET Barcode 4012345235636 British Royal Mail 4-State BPO 1234567895 Advanced imaging barcode scanner...
Page 93
ROGRAMMING UIDE Infomail Mail 4-State Sweden Post 4-State China Post Advanced imaging barcode scanner...
Page 94
ROGRAMMING UIDE USPS 4-state (Intelligent Mail) Barcode ID..82 Service Type ID..152 Mailer ID..568794 Serial Number..748970563 ZIP Code...12789600178 Barcode ID..00 Service Type ID..311 Mailer ID..000479 Serial Number..612518080 ZIP Code...20724170703 Barcode ID..20 Service Type ID..301 Mailer ID..901212001 Serial Number..311323 ZIP Code...20724170703 Advanced imaging barcode scanner...
ROGRAMMING UIDE Save To save the setting, scan the barcode below. Save Discard To correct an error or change a selection, scan the barcode below. Discard Advanced imaging barcode scanner...
ROGRAMMING UIDE Appendix E Full ASCII Table ASCII Hexacode ASCII Hexacode Full ASCII ---SI Full ASCII ---NUL Function key-----“Shift” Full ASCII ---SOH Full ASCII ---DLE Function key-----“Ins” Function key-----“5(num)” Full ASCII ---STX Full ASCII ---DC1 Function key-----“Del” Function key-----“F1” Full ASCII ---ETX Full ASCII ---DC2 Function key-----“Home”...
Page 100
ROGRAMMING UIDE Full ASCII ---RS Full ASCII ---- Function key-----“CTL(L)” Full ASCII ---US Full ASCII ---. Function key-----“ALT(L)” Full ASCII ---SP Full ASCII ---/ Full ASCII ---! Full ASCII ---0 Full ASCII ---“ Full ASCII ---1 Full ASCII ---# Full ASCII ---2 Full ASCII ---$ Full ASCII ---3 Full ASCII ---%...
Page 101
ROGRAMMING UIDE Full ASCII ---@ Full ASCII ---O Full ASCII ---A Full ASCII ---P Full ASCII ---B Full ASCII ---Q Full ASCII ---C Full ASCII ---R Full ASCII ---D Full ASCII ---S Full ASCII ---E Full ASCII ---T Full ASCII ---F Full ASCII ---U Full ASCII ---G Full ASCII ---V...
Page 102
ROGRAMMING UIDE Full ASCII ---b Full ASCII ---q Full ASCII ---c Full ASCII ---r Full ASCII ---d Full ASCII ---s Full ASCII ---e Full ASCII ---t Full ASCII ---f Full ASCII ---u Full ASCII ---g Full ASCII ---v Full ASCII ---h Full ASCII ---w Full ASCII ---x Full ASCII ---|...
Need help?
Do you have a question about the S302D and is the answer not in the manual?
Questions and answers