5.11.2. Cross-sensitivity data

Carbon Monoxide
Sulfur Dioxide
Nitric Dioxide
Hydrogen Sulfide
Figure: Cross-sensitivity data for the NO Sensor for low concentrations
You can find a complete example code for reading the NO Sensor for low concentrations in the following link:
www.libelium.com/development/waspmote/examples/scp-v30-01-electrochemical-gas-sensors
Gas
Formula
CO
SO
NO
H
Concentration
(ppm)
300
5
2
5
2
S
15
2
-57-
Output Signal
(ppm NO
equivalent)
0
0
1.5
-1.5
Sensors