Hoshizaki IM-30CNE Service Manual page 61

Self-contained cuber
Hide thumbs Also See for IM-30CNE:
Table of Contents

Advertisement

MODEL
IM-100 "N"-21 type
IM-130 "N" type
IM-240 "N" type
IM-240 "N"-21 type
IM-240 "N"-32 type
Note: The above data are only for reference in servicing. Actual readings may be slightly different
for each product.
Suction Pressure = Peak readings in freezing cycle
Evaporator Inlet Temp. = 5 minutes before completion of freezing cycle
Ambient Temp. (°C)
Water Temp. (°C)
Suction Pressure Peak (bar)
Evaporator Inlet Temp. (°C)
Suction Pressure Peak (bar)
Evaporator Inlet Temp. (°C)
Suction Pressure Peak (bar)
Evaporator Inlet Temp. (°C)
Suction Pressure Peak (bar)
Evaporator Inlet Temp. (°C)
Suction Pressure Peak (bar)
Evaporator Inlet Temp. (°C)
10
10
1.2
1.5
-13
-11
3.0
3.5
-20
-19
3.0
3.5
-20
-19
3.0
3.5
-13
-11
3.0
3.5
-23
-22
57
21
32
15
21
1.8
-10
4.0
-18
4.0
-18
4.0
-10
4.0
-21
38
32
2.2
-9.0
5.0
-17
5.0
-17
5.0
-9
5.0
-20

Hide quick links: