3. Testing communications and
completing EZ Setup
1. Using datalogger support software EZ Setup, access the Communication Test window. This
window is accessed during EZ Setup (see
more information). Alternatively, you can double-click a datalogger from the station list to
open the EZ Setup Wizard and access the Communication Test step from the left side of
the window.
2. Ensure the datalogger is connected to the computer, select Yes to test communications,
then click Next to initiate the test.
3. With a successful connection, the Datalogger Clock window displays the time for both the
datalogger and the computer.
The Adjusted Server Date/Time displays the current reading of the clock for the com-
l
puter or server running your datalogger support software. If the Datalogger
Date/Time and Adjusted Server Date/Time don't match, you can set the datalogger
clock to the Adjusted Server Date/Time by clicking Set Datalogger Clock.
Use the Time Zone Offset to specify a positive or negative offset to apply to the com-
l
puter time when setting the datalogger clock. This offset will allow you to set the
clock for a datalogger that needs to be set to a different time zone than the time
zone of the computer (or to accommodate for changes in daylight saving time).
4. Click Next.
5. The datalogger ships with a default QuickStart program. If the datalogger does not have a
program, you can choose to send one by clicking Select and Send Program. Click Next.
6. LoggerNet only - Watch a
The Datalogger Table Output Files window displays the data tables available to be
l
collected from the datalogger and the output file name. By default, all data tables set
up in the datalogger program will be included for collection. Make note of the Out-
put File Name and location. Click Next.
Check Scheduled Collection Enabled to have LoggerNet automatically collect data
l
from the datalogger according to a schedule. When the Base Date and Time are in
USB or RS-232 communications
video
or use the following instructions: