seal and spacer replacement (continued)
15. While the tool is still in the valve, press another seal
into the inside diameter of the exposed brass sleeve
end.
16. Remove the stuffer, turn it end for end, and insert it
into the valve body bore.
17. Alternately repeat steps No. 13 and 14 until all seals
and spacers have been pushed into the valve (See
valve cross section of your valve).
18. Place recommended silicone lubricant on the piston
and inside the valve.
19. Hold the back plate with one hand and guide the
piston into the valve body with the other hand, then
grasp the back plate on both sides and slowly push
the piston assembly and end plug assembly into the
valve (See Fig. 1).
20. Replace the two PH screws to hold the back plate to
the valve and tighten securely.
21. Connect the brine line form the injector housing to the
brine valve (if your unit has timed brine tank fill).
22. Set the time of day dial to the correct time.
23. Replace the electrical plug in the outlet.
24. Turn on water supply.
25. Cycle control and check for proper function.
26. Check by-pass valve.
Page 32
Figure 5 Placing Seal In Brass Sleeve Of Special Tool
Figure 6 Removing Special Tool From Valve Body
After Inserting Tool