Pentair Fleck 2510 Service Manual page 15

Hide thumbs Also See for Fleck 2510:
Table of Contents

Advertisement

MODEL 3210
regeneration cycle program setting procedure
How to Set The Regeneration Cycle Program:
The regeneration cycle program on your water conditioner
has been factory preset, however, portions of the cycle or
program may be lengthened or shortened in time to suit
local conditions.
If unit has a meter, disconnect meter cable from meter
at this time.
To expose cycle program wheel, grasp timer in upper left-
hand corner and pull, releasing snap retainer and swinging
timer to the right. (meter cable must be disconnected)
To change the regeneration cycle program, the program
wheel must be removed. Grasp program wheel and
squeeze protruding lugs towards center, lift program wheel
off timer. (Switch arms may require movement to facilitate
removal.)
How To Change The Length Of The Backwash Time:
The program wheel as shown in the drawing is in the
service position. As you look at the numbered side of the
program wheel, the group of pins starting at zero
determines the length of time your unit will backwash.
FOR EXAMPLE: If there are six pins in this section, the
time of backwash will be 12 min. (2 min. per pin). to
change the length of backwash time, add or remove pins
as required. The number of pins times two equals the
backwash time in minutes.
How To Change The Length of Brine and Rinse Time:
The group of holes between the last pin in the backwash
section and the second group of pins determines the
length of time that your unit will brine and rinse. (2 min. per
hole.)
To change the length of brine and rinse time, move the
rapid rinse group of pins to give more or fewer holes in the
brine and rinse section. Number of holes times two equals
brine and rinse time in minutes.
How To Change The Length Of Brine Tank Refill Sepa-
rate From Rapid Rinse: STF Black Cams
The second group of pins on the program wheel
determines the length of time that your water conditioner
will rapid rinse. (2 min. per pin.)
To change the length of rapid rinse time, add or remove
pins at the higher numbered end of this section as
required. The number of pins times two equals the rapid
rinse time in minutes.
How To Change The Length Of Brine Tank Refill Time:
The second group of holes on the program wheel
determines the length of time that your water conditioner
will refill the brine tank. (2 min. per hole.)
BRINE & RINSE
SECTION
(2 MIN. PER HOLE)
PIN STORAGE
BACKWASH
SECTION
(2 MIN. PER PIN)
To change the length of refill time, move the two pins at
the end of second group of holes as required.
The regeneration cycle is complete when the outer micro-
switch is tripped by the two pinset at end of the brine tank
refill section. The program wheel, however, will continue to
rotate until the inner micro-switch drops into the notch on
the program wheel.
How To Change The Length Of Rapid Rinse And Brine
Tank Fill Time: RR White Cams
The second group of pins on the program wheel
determines the length of time that your water conditioner
will rapid rinse and brine tank fill. (2 min. per pin.)
To change the length of rapid rinse and brine tank fill time,
add or remove pins at the higher numbered end of this
sections as required. The number of pins times two equals
the rapid rinse and brine tank fill time in minutes.
The regeneration cycle is complete when the outer micro-
switch drops off the last pin in the rapid rinse and brine
tank fill group of pins. The program wheel, however, will
continue to rotate until the inner micro-switch drop into the
notch on the program wheel.
Return timer to closed position engaging snap retainer
in back plate. Make certain all electrical wires locate
above snap retainer post and the meter cable slides
though the backplate and does not bind. Reconnect meter
cable.
PROGRAM
WHEEL FOR
CONTROL OF
REGENERATION
CYCLE
RAPID
RINSE
SECTION
(2 MIN.
PER PIN)
BRINE TANK
REFILL
SECTION
(2 MIN.
PER HOLE)
SEPERATE TIME
FILL ONLY
Page 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fleck 2510 econominder

Table of Contents